The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Continuous-Flow Microextraction Exceeding1000-Fold Concentration of Dilute Analytes
Abstract
A novel liquid-liquid microextraction method, that we have termed continuous-flow microextraction (CFME), is described. In a 0.5-mL glass chamber, an organic drop (1-5 microL) is held at the outlet tip of a polyetheretherketone (PEEK) connecting tubing which is immersed in a continuously flowing sample solution and acts as the fluid delivery duct and as a solvent holder. Extraction takes place between the organic drop and the flowing sample solution that is continuously ejected out of the PEEK tubing. Concentration factors of between 260- to 1600-fold are achieved within 10 min of extraction. Aspects relevant to CFME were studied. In combination with gas chromatography-electron capture detection, CFME allows analytes to be detected at femtogram-per-milliliter levels. The performance of this technique was evaluated on the basis of the analysis of trace nitroaromatic compounds and chlorobenzenes in environmental samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Cited by
Sarafraz-Yazdi, A., & Amiri, A. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.10.003 · Cited by 779
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2009) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2008.10.042 · Cited by 414
Developments in single-drop microextraction
Psillakis, E., & Kalogerakis, N. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(01)00126-1 · Cited by 373
The role of green extraction techniques in Green Analytical Chemistry
Armenta, S., Garrigues, S., & de la Guardia, M. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.12.011 · Cited by 329
Chen, Y., Guo, Z., Wang, X., & Qiu, C. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.026 · Cited by 316
Metadata
- Authors
- Liu, W., & Lee, H. K.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-08-10
- Volume
- 72
- Issue
- 18
- Pages
- 4462-4467
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2005405796
- Cited by
- 189
- References
- 1
- FWCI
- 2.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous-Flow Microextraction Exceeding1000-Fold Concentration of Dilute Analytes. https://app.cochat.ai/papers/10.1021/ac000240x
- The paper
- Liu, W., & Lee, H. K. (2000). Continuous-Flow Microextraction Exceeding1000-Fold Concentration of Dilute Analytes. Analytical Chemistry. https://doi.org/10.1021/ac000240x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.