The DOI matches its Crossref record.
Comprehensive Two-Dimensional Gas Chromatography via Differential Flow Modulation
Abstract
A novel comprehensive two-dimensional gas chromatograph has been developed that utilizes differential flow modulation. This technique uses a 6-port valve to collect effluent from a primary column and periodically inject the effluent into a secondary column. The flow in the secondary column is kept 20 times larger than the flow in the primary column so the contents of the sample loop can be flushed into the secondary column in 5% of the collection time. Peaks widths at half-maximum of approximately 0.06 s are generated for a 1.0 Hz secondary injection frequency. Sensitivity is not compromised, as 80% of the sample passes through both columns and reaches the detector. This simple yet effective technique has been used to analyze mixtures of alkanes, alkenes, aldehydes, alcohols, aromatics, esters, and ketones with high speed and high resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Comprehensive two-dimensional gas chromatography: a powerful and versatile analytical tool
Dallüge, J., Beens, J., & Brinkman, U. A. T. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00242-5 · Cited by 587
Principles and applications of comprehensive two-dimensional gas chromatography
Marriott, P., & Shellie, R. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(02)00814-2 · Cited by 282
A New Dimension in Separation Science: Comprehensive Two‐Dimensional Gas Chromatography
Meinert, C., & Meierhenrich, U. J. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200842 · Cited by 106
Metadata
- Authors
- Seeley, J. V., Kramp, F., & Hicks, C. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-08-17
- Volume
- 72
- Issue
- 18
- Pages
- 4346-4352
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1971796147
- Cited by
- 163
- References
- 0
- FWCI
- 5.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.