Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 241

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Integration of mass spectrometry in analytical biotechnology

Carr, Steven A., Hemling, Mark E., Bean, Mark F., Roberts, Gerald D.·1991·Analytical Chemistry

Abstract

Mass spectrometry (MS) has become an indispensable tool for peptide and protein structure analysis because of three unique capabilities that enable it to be used to solve structural problems not easily handled by conventional techniques. First, MS is able to provide accurate molecular weight information on low-picomole amounts of peptides and proteins independent of covalent modifications that may be present. Second, this information is obtainable for peptides present in complex mixtures such as those that result from a proteolytic digest of a protein. Third, by using tandem MS, partial to complete sequence information may be obtained for peptides containing up to 25 amino acid residues, even if the peptides are present in mixtures. Sensitivity and speed of the MS-based approaches now equal (and in some cases exceed) that of Edman-based sequence analysis. In this perspective we discuss how MS, tandem high-performance MS, and on-line liquid chromatography/MS using fast atom bombardment or electrospray ionization have been integrated with more conventional techniques in order to increase the accuracy and speed of peptide and protein structure characterization. The expanding role of matrix-assisted laser desorption MS in protein analysis is also described. The unique niche that MS occupies for locating and structurally characterizing posttranslational modifications of proteins is emphasized. Examples chosen from the authors' laboratory illustrate how MS is used to sequence blocked proteins, define N- and C-terminal sequence heterogeneity, locate and correct errors in DNA- and cDNA-deduced protein sequences, identify sites of deamidation, isoaspartyl formation, phosphorylation, oxidation, disulfide bond formation, and glycosylation, and define the structural class of carbohydrate at specific attachment sites in glycoproteins.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac00024a003

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Metadata

Authors
Carr, S. A., Hemling, M. E., Bean, M. F., & Roberts, G. D.
Venue
Analytical Chemistry
Published
1991-12-15
Volume
63
Issue
24
Pages
2802-2824
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1980712779
Cited by
241
References
4
FWCI
18.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Integration of mass spectrometry in analytical biotechnology. https://app.cochat.ai/papers/10.1021/ac00024a003
The paper
Carr, S. A., Hemling, M. E., Bean, M. F., & Roberts, G. D. (1991). Integration of mass spectrometry in analytical biotechnology. Analytical Chemistry. https://doi.org/10.1021/ac00024a003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.