Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 163

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

High sensitivity tracer detection using high-precision gas chromatography-combustion isotope ratio mass spectrometry and highly enriched uniformly carbon-13 labeled precursors

Goodman, Keith J., Brenna, J. Thomas.·1992·Analytical Chemistry

Abstract

The use of highly enriched, uniformly labeled fatty acid ([U-13C]) with analysis by high-precision gas chromatography-combustion isotope ratio mass spectrometry (GCC-IRMS) has been evaluated as a metabolic tracer technique. 13C/12C ratios are routinely determined to precisions (SD) of less than 0.00001 (delta PDB less than 1/1000) for greater than 10 ng of fatty acid, and less than 0.001 (delta PDB less than 100/1000) for samples of 30 pg of fatty acid, the latter corresponding to a 100-fmol sample. Baseline fatty acid 13C/12C in human plasma fractions is shown to fluctuate not more than 0.000 04 (delta PDB 4/1000) over 10 h. 13C/12C enrichments greater than 0.001 (delta PDB 100/1000) are obtained in a fatty acid plasma fraction subsequent to a 10-mg dose of 42% 13C-labeled stearic acid to a 78-kg adult. Biokinetics are discerned over an 13C/12C enrichment range of less than 0.0002 (approximately 13/1000 in delta PDB units) in plasma. A means for correction of isotope ratio contamination due to carbon-containing derivatives is presented. High-precision GCC-IRMS used in concert with highly enriched tracers is shown to possess advantages versus organic GC/MS for stable isotopic tracer detection and is superior to radiotracer methods in terms of dose sizes and analysis efficiency.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac00034a004

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 163

Metadata

Authors
Goodman, K. J., & Brenna, J. T.
Venue
Analytical Chemistry
Published
1992-05-15
Volume
64
Issue
10
Pages
1088-1095
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2045947722
Cited by
163
References
1
FWCI
4.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High sensitivity tracer detection using high-precision gas chromatography-combustion isotope ratio mass spectrometry and highly enriched uniformly carbon-13 labeled precursors. https://app.cochat.ai/papers/10.1021/ac00034a004
The paper
Goodman, K. J., & Brenna, J. T. (1992). High sensitivity tracer detection using high-precision gas chromatography-combustion isotope ratio mass spectrometry and highly enriched uniformly carbon-13 labeled precursors. Analytical Chemistry. https://doi.org/10.1021/ac00034a004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.