CoChat

Analysis of diffusional broadening of vesicular packets of catecholamines released from biological cells during exocytosis

Schroeder, Timothy J., Jankowski, Jeffrey A., Kawagoe, Kirk T., Wightman, R. Mark., Lefrou, Christine., Amatore, Christian. · 1992 · Analytical Chemistry
Cited by 150

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Secretion of catecholamines is observed as a series of current spikes when measured at the surface of a bovine adrenal medullary cell in culture with a carbon-fiber microelectrode operated in the amperometric mode. Prior work has shown that these spikes are due to detection of concentrated packets of catecholamines which are released from individual vesicles after their fusion with the cell membrane, a process known as exocytosis. The shape of the individual current spikes, detected with a 5-microns spacing between the hemispherical cell and the electrode, has been compared to the shape generated by a theoretical model. The model consists of an instantaneous point source of material on a surface which subsequently diffuses to a disk that consumes the emitted material. The pertinent diffusion conditions have been evaluated with finite difference and random walk digital simulations. The two methods give identical results when the point source is located on a plane. The more realistic simulation geometry, emission from a hemispherical surface, was evaluated with the random walk method. The simulations allow a set of criteria to be established to evaluate diffusion-controlled broadening of spike shape. The broad range of spike widths observed experimentally and their individual shapes measured with 5-microns cell-electrode spacing are consistent with diffusion from point sources randomly distributed across a hemispherical surface. The data can be described with the diffusion coefficient for catecholamines in free solution. The model enables evaluation of signal-to-noise losses and correction for diffusional losses which are dependent on electrode radius.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac00048a003

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 150

Metadata

Authors
Schroeder, T. J., Jankowski, J. A., Kawagoe, K. T., Wightman, R. M., Lefrou, C., & Amatore, C.
Venue
Analytical Chemistry
Published
1992-12-15
Volume
64
Issue
24
Pages
3077-3083
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1988712581
Cited by
150
References
2
FWCI
6.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analysis of diffusional broadening of vesicular packets of catecholamines released from biological cells during exocytosis. https://app.cochat.ai/papers/10.1021/ac00048a003
The paper
Schroeder, T. J., Jankowski, J. A., Kawagoe, K. T., Wightman, R. M., Lefrou, C., & Amatore, C. (1992). Analysis of diffusional broadening of vesicular packets of catecholamines released from biological cells during exocytosis. Analytical Chemistry. https://doi.org/10.1021/ac00048a003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.