Cited by 817Cellular transport and secretionElectrochemical Analysis and ApplicationsNeuroscience and Neuropharmacology Research

Delay in vesicle fusion revealed by electrochemical monitoring of single secretory events in adrenal chromaffin cells

Chow, Robert H., von Rüden, Ludolf, Neher, Erwin·1992·Nature

Abstract

In synapses, a rise in presynaptic intracellular calcium leads to secretory vesicle fusion in less than a millisecond, as indicated by the short delay from excitation to postsynaptic signal. In nonsynaptic secretory cells, studies at high time resolution have been limited by the lack of a detector as fast and sensitive as the postsynaptic membrane. Electrochemical methods may be sensitive enough to detect catecholamines released from single vesicles. Here, we show that under voltage-clamp conditions, stochastically occurring signals can be recorded from adrenal chromaffin cells using a carbon-fibre electrode as an electrochemical detector. These signals obey statistics characteristic for quantal release; however, in contrast to neuronal transmitter release, secretion occurs with a significant delay after short step depolarizations. Furthermore, we identify a pedestal or 'foot' at the onset of unitary events which may represent the slow leak of catecholamine molecules out of a narrow 'fusion pore' before the pore dilates for complete exocytosis.

Integrity signals

Registry

Crossref · 10.1038/356060a0

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Insulin is not easily oxidized and is difficult to detect by carbon fiber amperometry, but both catecholamines and serotonin can be detected electrochemically.

    “Insulin is not easily oxidized and is difficult to detect by this method, but both catecholamines and serotonin can be detected electrochemically (119).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Chow, R. H., von Rüden, L., & Neher, E.
Affiliations
Max Planck Society (DE)
Venue
Nature
Published
1992-03
Volume
356
Issue
6364
Pages
60-63
ISSN
  • 0028-0836 (ISSN-L)
  • 1476-4687
OpenAlex
W2033067408
Cited by
817
References
1
Citations by year
2026: 7 · 2025: 5 · 2024: 7 · 2023: 8 · 2022: 13 · 2021: 16 · 2020: 18 · 2019: 13 · 2018: 22 · 2017: 19 · 2016: 18 · 2015: 20 · 2014: 24 · 2013: 24 · 2012: 23
FWCI
15.40
Type
journal article
Language
en
Open access
closed
Locations
  • Nature (publishedVersion)
  • PubMed (publishedVersion)
  • Max Planck Institute for Plasma Physics (submittedVersion)
  • MPG.PuRe (Max Planck Society) (submittedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular transport and secretion
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neuropharmacology Research
Keywords
vesicle fusion, adrenal chromaffin cells, catecholamine release, electrochemical detection, carbon fiber electrodes, quantal release, fusion pore, exocytosis, voltage clamp
MeSH terms
Adrenal Medulla, Animals, Catecholamines, Cattle, Chromaffin Granules, Electric Conductivity, Exocytosis, Mathematics, Stochastic Processes

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review