The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Heat-induced conformational changes in proteins studied by electrospray ionization mass spectrometry
Abstract
A simple and effective device for investigating heat-induced denaturation of proteins by electrospray ionization mass spectrometry is described. Results are presented for the denaturation as a function of temperature and solution pH of bovine ubiquitin and bovine cytochrome c. These results are in concert with and extend the earlier results of LeBlanc et al. (Org. Mass Spectrom. 1991, 26, 831). The cooperative effects of pH and temperature on the denaturation of ubiquitin and cytochrome c were investigated. Electrospray ionization mass spectrometry is also shown to be a useful probe of the reversibility of heat-induced denaturation of proteins. Finally, it is demonstrated that heat-induced denaturation can be used to improve the mass spectrometric response of proteins that do not normally yield useful spectra when the solubilized protein is electrosprayed at ambient temperatures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Structure of ubiquitin refined at 1.8 Å resolution
Vijay-kumar, S., Bugg, C. E., & Cook, W. J. (1987) · Journal of Molecular Biology · doi:10.1016/0022-2836(87)90679-6 · Cited by 1,742
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Dill, K. A., & Shortle, D. (1991) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.60.070191.004051 · Cited by 874
Katta, V., & Chait, B. T. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00022a058 · Cited by 475
Self-citationLoo, J. A., Loo, R. R. O., Udseth, H. R., Edmonds, C. G., & Smith, R. D. (1991) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290050303 · Cited by 291
Method for the electrospray ionization of highly conductive aqueous solutions
Chowdhury, S. K., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00015a030 · Cited by 137
Self-citationAre the electrospray mass spectra of proteins related to their aqueous solution chemistry?
Guevremont, R., Siu, K. W. M., Blanc, J. C. Y. L., & Berman, S. S. (1992) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(92)87005-j · Cited by 134
Design and performance of a novel electrospray interface
Allen, M. H., & Vestal, M. L. (1992) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(92)85014-b · Cited by 123
Cary, P. D., KING, D. S., Crane‐Robinson, C., Bradbury, E. M., Rabbani, A., Goodwin, G. H., & Johns, E. W. (1980) · European Journal of Biochemistry · doi:10.1111/j.1432-1033.1980.tb06123.x · Cited by 100
Thermal denaturation of some proteins and its effect on their electrospray mass spectrat
Blanc, J. C. Y. L., Beuchemin, D., Siu, K. W. M., Guevremont, R., & Berman, S. S. (1991) · Organic Mass Spectrometry · doi:10.1002/oms.1210261005 · Cited by 86
Cited by
Mass Spectrometry in Proteomics
Aebersold, R., & Goodlett, D. R. (2001) · Chemical Reviews · doi:10.1021/cr990076h · Cited by 1,238
From ions in solution to ions in the gas phase - the mechanism of electrospray mass spectrometry
Kebarle, P., & Tang, L. (1993) · Analytical Chemistry · doi:10.1021/ac00070a001 · Cited by 781
Investigation of intact protein complexes by mass spectrometry
Heck, A. J. R., & van den Heuvel, R. H. H. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.10081 · Cited by 583
Tang, L., & Kebarle, P. (1993) · Analytical Chemistry · doi:10.1021/ac00072a020 · Cited by 506
Biomolecule Analysis by Ion Mobility Spectrometry
Bohrer, B. C., Merenbloom, S. I., Koeniger, S. L., Hilderbrand, A. E., & Clemmer, D. E. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113001 · Cited by 492
Metadata
- Authors
- Mirza, U. A., Cohen, S. L., & Chait, B. T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1993-01-01
- Volume
- 65
- Issue
- 1
- Pages
- 1-6
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1980310871
- Cited by
- 256
- References
- 10
- FWCI
- 14.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.