The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Investigation of intact protein complexes by mass spectrometry
Open accessAbstract
I. Introduction 00 II. Electrospray Ionization of Biomacromolecules 00 III. Mass Analyzers for Biomacromolecular Mass Spectrometry 00 A. Collisional Cooling and/or Focusing 00 B. Alternative Mass Analyzers 00 IV. Solution‐Phase Properties of Proteins Complexes 00 A. Protein–Protein Interactions 00 B. Cooperativity and Cofactors 00 C. Dynamics of Assembly 00 V. Gas‐Phase Properties of Protein Complexes 00 A. Tandem Mass Spectrometry 00 B. Charge Separation in Protein Dissociation 00 VI. Future Outlook 00 Acknowledgments 00 References 00 Mass spectrometry has grown in recent years to a well‐accepted and increasingly important complementary technique in structural biology. Especially electrospray ionization mass spectrometry is well suited for the detection of non‐covalent protein complexes and their interactions with DNA, RNA, ligands, and cofactors. Over the last decade, significant advances have been made in the ionization and mass analysis techniques, which makes the investigation of even larger and more heterogeneous intact assemblies feasible. These technological developments have paved the way to study intact non‐covalent protein–protein interactions, assembly and disassembly in real time, subunit exchange, cooperativity effects, and effects of cofactors, allowing us a better understanding of proteins in cellular processes. In this review, we describe some of the latest developments and several highlights. © 2004 Wiley Periodicals, Inc., Mass Spec Rev
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Covey, T. R., Huang, E. C., & Henion, J. D. (1991) · Analytical Chemistry · doi:10.1021/ac00013a003 · Cited by 446
Cited by
McDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
Native mass spectrometry: a bridge between interactomics and structural biology
Heck, A. J. R. (2008) · Nature Methods · doi:10.1038/nmeth.1265 · Cited by 766
Self-citationNative Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602
“DNA [77], protein–drug [78], and protein–protein complexes [79, 80].”
Self-citationBreuker, K., & McLafferty, F. W. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0807005105 · Cited by 423
Metadata
- Authors
- Heck, A. J. R., & van den Heuvel, R. H. H.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2004-03-15
- Volume
- 23
- Issue
- 5
- Pages
- 368-389
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W2083486056
- Cited by
- 583
- References
- 4
- FWCI
- 15.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Investigation of intact protein complexes by mass spectrometry. https://app.cochat.ai/papers/10.1002/mas.10081
- The paper
- Heck, A. J. R., & van den Heuvel, R. H. H. (2004). Investigation of intact protein complexes by mass spectrometry. Mass Spectrometry Reviews. https://doi.org/10.1002/mas.10081
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.