The DOI matches its Crossref record.
A Quantitative Assessment of Heterogeneity for Surface-Immobilized Proteins
Abstract
Many biotechnological applications use protein receptors immobilized on solid supports. Although, in solution, these receptors display homogeneous binding affinities and association/dissociation kinetics for their complementary ligand, they often display heterogeneous binding characteristics after immobilization. In this study, a fluorescence-based fiber-optic biosensor was used to quantify the heterogeneity associated with the binding of a soluble analyte, fluorescently labeled trinitrobenzene, to surface-immobilized monoclonal anti-TNT antibodies. The antibodies were immobilized on silica fiber-optic probes via five different immobilization strategies. We used the Sips isotherm to assesses and compare the heterogeneity in the antibody binding affinity and kinetic rate parameters for these different immobilization schemes. In addition, we globally analyzed kinetic data with a two-compartment transport-kinetic model to analyze the heterogeneity in the analyte-antibody kinetics. These analyses provide a quantitative tool by which to evaluate the relative homogeneity of different antibody preparations. Our results demonstrate that the more homogeneous protein preparations exhibit more uniform affinities and kinetic constants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A review on the utilization of fly ash
Ahmaruzzaman, M. (2010) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2009.11.003 · Cited by 2,641
Micro- and nanomechanical sensors for environmental, chemical, and biological detection
Waggoner, P. S., & Craighead, H. G. (2007) · Lab on a Chip · doi:10.1039/b707401h · Cited by 678
Label-free biological and chemical sensors
Hunt, H. K., & Armani, A. M. (2010) · Nanoscale · doi:10.1039/c0nr00201a · Cited by 371
Solid supports for microarray immunoassays
Kusnezow, W., & Hoheisel, J. D. (2003) · Journal of Molecular Recognition · doi:10.1002/jmr.625 · Cited by 277
Metadata
- Authors
- Vijayendran, R. A., & Leckband, D. E.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-12-23
- Volume
- 73
- Issue
- 3
- Pages
- 471-480
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2047187307
- Cited by
- 260
- References
- 0
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Quantitative Assessment of Heterogeneity for Surface-Immobilized Proteins. https://app.cochat.ai/papers/10.1021/ac000523p
- The paper
- Vijayendran, R. A., & Leckband, D. E. (2001). A Quantitative Assessment of Heterogeneity for Surface-Immobilized Proteins. Analytical Chemistry. https://doi.org/10.1021/ac000523p
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.