Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 213

The DOI matches its Crossref record.

Amperometric sensors for peroxide, choline, and acetylcholine based on electron transfer between horseradish peroxidase and a redox polymer

Garguilo, Michael G., Nhan Huynh, ., Proctor, Andrew., Michael, Adrian C.·1993·Analytical Chemistry

Abstract

Amperometric sensors have been developed for hydrogen peroxide, choline, and acetylcholine by immobilization of horseradish peroxidase, (HRP), choline oxidase, and acetylcholinesterase in a cross-linked redox polymer deposited on glassy carbon electrodes. Peroxide sensors, prepared by immobilization of HRP alone, gave detection limits of 10 nM and a linear response up to ca. 1 mM. Coimmobilization of HRP and glucose oxidase was used to establish the feasibility of highly efficient bienzyme sensors at low substrate levels. Replacing glucose oxidase with choline oxidase produced sensors with submicromolar detection limits and a linear response up to 0.8 mM. Addition of acetylcholinesterase to the sensors generated a relatively small response to acetylcholine that demonstrates the feasibility of trienzyme sensors. At low substrate concentrations, no loss in sensitivity during a 1-day experiment was observed. The response times of these sensors are all less than 30 s with 2-s response times achieved in some cases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac00053a007

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Metadata

Authors
Garguilo, M. G., Nhan Huynh, Proctor, A., & Michael, A. C.
Venue
Analytical Chemistry
Published
1993-03-01
Volume
65
Issue
5
Pages
523-528
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1994487420
Cited by
213
References
0
FWCI
14.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Amperometric sensors for peroxide, choline, and acetylcholine based on electron transfer between horseradish peroxidase and a redox polymer. https://app.cochat.ai/papers/10.1021/ac00053a007
The paper
Garguilo, M. G., Nhan Huynh, Proctor, A., & Michael, A. C. (1993). Amperometric sensors for peroxide, choline, and acetylcholine based on electron transfer between horseradish peroxidase and a redox polymer. Analytical Chemistry. https://doi.org/10.1021/ac00053a007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.