CoChat

Capillary Electrophoresis−Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Using a Vacuum Deposition Interface

Preisler, Jan, Hu, Ping, Rejtar, Tomas, Karger, Barry L. · 2000 · Analytical Chemistry
Cited by 115

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

An improved vacuum deposition interface for coupling capillary electrophoresis with MALDI-TOF MS has been developed. Liquid samples consisting of analyte and matrix were deposited on a moving tape in the evacuated source chamber of a TOF mass spectrometer, enabling 24 h of uninterrupted analysis. The vacuum deposition procedure was compared with the dried-droplet method, and it was found that vacuum deposition generated significantly more reproducible signal intensity, eliminating the need for "sweet spot" searching. A concentration detection limit in the low-nanomolar range has been achieved with a low-attomole amount of sample consumed per spectrum. In addition, ion suppression caused by hydrophobicity differences in the analytes was reduced. To minimize ion suppression further, separation prior to MALDI MS analysis was employed. The performance of capillary electrophoresis (CE)-MALDI-TOF MS using the vacuum deposition interface was evaluated with a peptide mixture injected at low-femtomole levels. All peptides were baseline resolved with separation efficiencies in the range of 250000-400000 plates/m (2-3-s band half-width), demonstrating the high separation efficiency of the CE-MALDI MS coupling. A fast (approximately 40 s) CE separation of a mixture of angiotensins was found to reduce significantly ion suppression and enable trace level detection. It was also shown, for the analysis of an enolase digest, that sequence coverage of 65% was obtained using CE separation compared to 52% using step-elution solid-phase extraction and 44% in the control experiment using an unseparated mixture.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac0005870

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 115

Metadata

Authors
Preisler, J., Hu, P., Rejtar, T., & Karger, B. L.
Venue
Analytical Chemistry
Published
2000-09-15
Volume
72
Issue
20
Pages
4785-4795
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2047769739
Cited by
115
References
1
FWCI
6.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.