Capillary Electrophoresis−Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Using a Vacuum Deposition Interface
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
An improved vacuum deposition interface for coupling capillary electrophoresis with MALDI-TOF MS has been developed. Liquid samples consisting of analyte and matrix were deposited on a moving tape in the evacuated source chamber of a TOF mass spectrometer, enabling 24 h of uninterrupted analysis. The vacuum deposition procedure was compared with the dried-droplet method, and it was found that vacuum deposition generated significantly more reproducible signal intensity, eliminating the need for "sweet spot" searching. A concentration detection limit in the low-nanomolar range has been achieved with a low-attomole amount of sample consumed per spectrum. In addition, ion suppression caused by hydrophobicity differences in the analytes was reduced. To minimize ion suppression further, separation prior to MALDI MS analysis was employed. The performance of capillary electrophoresis (CE)-MALDI-TOF MS using the vacuum deposition interface was evaluated with a peptide mixture injected at low-femtomole levels. All peptides were baseline resolved with separation efficiencies in the range of 250000-400000 plates/m (2-3-s band half-width), demonstrating the high separation efficiency of the CE-MALDI MS coupling. A fast (approximately 40 s) CE separation of a mixture of angiotensins was found to reduce significantly ion suppression and enable trace level detection. It was also shown, for the analysis of an enolase digest, that sequence coverage of 65% was obtained using CE separation compared to 52% using step-elution solid-phase extraction and 44% in the control experiment using an unseparated mixture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
The Desorption Process in MALDI
Dreisewerd, K. (2003) · Chemical Reviews · doi:10.1021/cr010375i · Cited by 709
Sol-Gel processing of silica nanoparticles and their applications
Singh, L. P., Bhattacharyya, S. K., Kumar, R., Mishra, G., Sharma, U., Singh, G., & Ahalawat, S. (2014) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2014.10.007 · Cited by 428
Capillary electrophoresis – mass spectrometry: 15 years of developments and applications
Schmitt‐Kopplin, P., & Frommberger, M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305659 · Cited by 289
Krokhin, O. V., Craig, R., Spicer, V., Ens, W., Standing, K. G., Beavis, R. C., & Wilkins, J. A. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400031-mcp200 · Cited by 284
“trace vacuum deposition (22, 23), and a similar deposition From the ‡Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB, R3T 2N2, Canada; and §Manitoba Centre for Proteomics, University of Manitoba, Winnipeg, MB, R3E 3P4, Canada Received, February 26, 2004, and in revised form, July 6, 2004 Publ…”
BackgroundCapillary electrophoresis–mass spectrometry for the analysis of intact proteins
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.048 · Cited by 185
Glycomic analysis by capillary electrophoresis–mass spectrometry
Mechref, Y., & Novotny, M. V. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20196 · Cited by 105
Capillary electrophoresis applied to proteomic analysis
Fonslow, B. R., & Yates III, J. R. (2009) · Journal of Separation Science · doi:10.1002/jssc.200800592 · Cited by 92
Analysis of glycans derived from glycoconjugates by capillary electrophoresis‐mass spectrometry
Mechref, Y. (2011) · ELECTROPHORESIS · doi:10.1002/elps.201100342 · Cited by 64
Metadata
- Authors
- Preisler, J., Hu, P., Rejtar, T., & Karger, B. L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-09-15
- Volume
- 72
- Issue
- 20
- Pages
- 4785-4795
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2047769739
- Cited by
- 115
- References
- 1
- FWCI
- 6.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.