Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 552

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Sequence-selective biosensor for DNA based on electroactive hybridization indicators

Millan, Kelly M., Mikkelsen, Susan R.·1993·Analytical Chemistry

Abstract

Deoxyribonucleic acid was covalently immobilized onto oxidized glassy carbon electrode surfaces that had been activated using 1-[3-(dimethylamino)-propyl]-3-ethylcarbodimide hydrochloride and N-hydroxysulfosuccinimide. This reaction is selective for immobilization through deoxyguanosine (dG) residues. Immobilized DNA was detected voltammetrically, using tris (2,2'-bipyridyl)cobalt(III) perchlorate and tris (1,10-phenanthroline)cobalt(III) perchlorate (Co(bpy)3(3+) and Co(phen)3(3+). These complexes are reversibly electroactive (1e-) and preconcentrate at the electrode surface through association with double-stranded DNA. Voltammetric peak currents obtained with a poly(dG)poly(dC)-modified electrode depend on [Co(bpy)3(3+)] and [Co(phen)3(3+)] in a nonlinear fashion and indicate saturation binding with immobilized DNA. Voltammetric peak currents for Co(phen)3(3+) reduction were used to estimate the (constant) local DNA concentration at the modified electrode surface; a binding site size of 5 base pairs and an association constant of 1.74 x 10(3) M(-1) yield 8.6 +/- 0.2 mM base pairs. Cyclic voltammetric peak separations indicate that heterogeneous electron transfer is slower at DNA-modified electrodes than at unmodified glassy carbon electrodes. A prototype sequence-selective DNA sensor was constructed by immobilizing a 20-mer oligo (deoxythymidylic acid) (oligo(dT)20), following its enzymatic elongation with dG residues, which yielded the species oligo(dT)20(dG)98. Cyclic voltammograms of 0.12 mM Co(bpy)3(3+) obtained before and after hybridization with poly-(dA) and oligo(dA)20 show increased cathodic peaks after hybridization. The single-stranded form is regenerated on the electrode surface by rinsing with hot deionized water. These results demonstrate the use of electroactive hybridization indicators in a reusable sequence-selective biosensor for DNA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac00065a025

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 552

Metadata

Authors
Millan, K. M., & Mikkelsen, S. R.
Venue
Analytical Chemistry
Published
1993-09-01
Volume
65
Issue
17
Pages
2317-2323
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2042386699
Cited by
552
References
1
FWCI
2.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sequence-selective biosensor for DNA based on electroactive hybridization indicators. https://app.cochat.ai/papers/10.1021/ac00065a025
The paper
Millan, K. M., & Mikkelsen, S. R. (1993). Sequence-selective biosensor for DNA based on electroactive hybridization indicators. Analytical Chemistry. https://doi.org/10.1021/ac00065a025

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.