The DOI matches its Crossref record.
Electrochemical Detection of Thiols with a Coenzyme Pyrroloquinoline Quinone Modified Electrode
Abstract
A modified electrode sensor for the detection of thiols is described. The sensor was constructed by incorporation of the coenzyme pyrroloquinoline quinone (PQQ) into a polypyrrole (PPy) film on a glassy carbon electrode substrate by the electropolymerization of pyrrole in the presence of PQQ. The electrochemical properties of entrapped PQQ in the PPy film were influenced by the applied potential during electropolymerization and by film thickness, both of which were optimized to yield a stable and reproducible response for entrapped PQQ. The PQQ/ PPy sensor was utilized for the amperometric detection of cysteine, homocysteine, penicillamine, N-acetylcysteine, and glutathione. The response for each thiol in pH 8.42 borate buffer was found to be linear with detection limits (S/N = 3) ranging from 13.2 microM for glutathione to 63.7 nM for cysteine with sensitivities of 0.023 nA/microM and 4.71 nA/microM, respectively. The response and detection limits were found to be sensitive to the nature of the thiol and the solution pH. Furthermore, in the presence of dopamine, ascorbic acid, or uric acid, the pH-dependent redox potential of the PQQ catalyst allows tuning of the detection potential to enhance the selectivity for thiols over these potential electroactive interferences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Thiol-addition reactions and their applications in thiol recognition
Yin, C., Huo, F., Zhang, J., Martínez-Máñez, R., Yang, Y., Lv, H., & Li, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60055f · Cited by 554
Analytical determination of homocysteine: a review
Nekrassova, O. (2003) · Talanta · doi:10.1016/s0039-9140(03)00173-5 · Cited by 310
N-Acetylcysteine interference with a glucose dehydrogenase linked glucose meter
Lyon, M. E., & Lyon, A. W. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/1932296821999416 · Cited by 10
Metadata
- Authors
- Inoue, T., & Kirchhoff, J. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-10-26
- Volume
- 72
- Issue
- 23
- Pages
- 5755-5760
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1991690458
- Cited by
- 229
- References
- 0
- FWCI
- 4.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical Detection of Thiols with a Coenzyme Pyrroloquinoline Quinone Modified Electrode. https://app.cochat.ai/papers/10.1021/ac000716c
- The paper
- Inoue, T., & Kirchhoff, J. R. (2000). Electrochemical Detection of Thiols with a Coenzyme Pyrroloquinoline Quinone Modified Electrode. Analytical Chemistry. https://doi.org/10.1021/ac000716c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.