N-Acetylcysteine Interference with a Glucose Dehydrogenase Linked Glucose Meter
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Background: Our objective was to determine the effect of therapeutic concentrations of N-acetylcysteine, following intravenous infusion, on the measurement of blood glucose using a Roche Diagnostics glucose dehydrogenase-linked glucose meter compared to hospital laboratory methods. Methods: N-acetylcysteine was added to aliquots of blood, with glucose promptly measured by the glucose meter, blood gas analyzer (glucose oxidase comparative method) and following centrifugation, plasma glucose measured with a hexokinase spectrophotometric comparative method. Glucose results were evaluated with linear regression and Bland Altman plots. Results: In the presence of NAC, at concentrations greater than 5 mg/dL (0.31 mmol/L), positively biased glucose meter results were compared to the clinical laboratory results. Multivariate linear regression revealed that NAC-mediated meter results are influenced by NAC and glucose concentrations. Conclusions: The addition of therapeutic concentrations of NAC to blood produces statistically significant positive biases when measured with the glucose dehydrogenase linked glucose meter device.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
N -acetylcysteine for antioxidant therapy: pharmacology and clinical utility
Dodd, S., Dean, O., Copolov, D. L., Malhi, G. S., & Berk, M. (2008) · Expert Opinion on Biological Therapy · doi:10.1517/14728220802517901 · Cited by 413
Pharmacokinetics and bioavailability of reduced and oxidized N-acetylcysteine
Olsson, B., Johansson, M., Gabrielsson, J., & Bolme, P. (1988) · European Journal of Clinical Pharmacology · doi:10.1007/bf01061422 · Cited by 351
Electrochemical Detection of Thiols with a Coenzyme Pyrroloquinoline Quinone Modified Electrode
Inoue, T., & Kirchhoff, J. R. (2000) · Analytical Chemistry · doi:10.1021/ac000716c · Cited by 229
The disposition and kinetics of intravenous N-acetylcysteine in patients with paracetamol overdosage
Prescott, L. F., Donovan, J. W., Jarvie, D. R., & Proudfoot, A. T. (1989) · European Journal of Clinical Pharmacology · doi:10.1007/bf00558131 · Cited by 185
Interferences and Limitations in Blood Glucose Self-Testing: An Overview of the Current Knowledge
Erbach, M., Freckmann, G., Hinzmann, R., Kulzer, B., Ziegler, R., Heinemann, L., & Schnell, O. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816641433 · Cited by 115 · cited 4×
“Determination of Partial Regression Coefficients by Linear Regression Models by Ordinary Least Squares for Equations (1) to (3).”
BackgroundMethodInfluentialPapi, A. A., Stefano, A. F. D. D., & Radicioni, M. M. (2020) · Advances in Therapy · doi:10.1007/s12325-020-01542-4 · Cited by 49
Perera, N. J., Stewart, P. M., Williams, P. F., Chua, E. L., Yue, D. K., & Twigg, S. M. (2011) · Diabetic Medicine · doi:10.1111/j.1464-5491.2011.03362.x · Cited by 33 · cited 4×
“There was no evidence of NAC associated bias with either the blood gas analyzer or chemistry laboratory glucose methods (equation (3)) where β2 = −0.”
MethodInfluentialN-acetylcysteine interference of Trinder-based assays
Genzen, J. R., Hunsaker, J. J. H., Nelson, L. S., Faine, B. A., & Krasowski, M. D. (2015) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2015.10.005 · Cited by 29 · cited 1×
“Genzen et al.,16 previously reported that supra-therapeutic NAC concentrations (up to 1000 mg/dL) inhibited several Trinder based assays on the Roche Cobas 8000 chemistry analyzer.”
MethodLyon, M. E., DuBois, J. A., Fick, G. H., & Lyon, A. W. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400624 · Cited by 27 · cited 1×
“Equation (2) depicts a similar model to predict meter whole blood glucose and the glucose by the plasma hexokinase method.”
MethodSelf-citationN-acetylcysteine protects against star fruit-induced acute kidney injury
Shimizu, M. H. M., Gois, P. H. F., Volpini, R. A., Canale, D., Luchi, W. M., Froeder, L., Heilberg, I. P., & Seguro, A. C. (2016) · Renal Failure · doi:10.1080/0886022x.2016.1256315 · Cited by 25
Research works printed but not linked: 2
- Roche, 2020, Accu-Chek® Inform II test strips- a new interfering substance has been found: N-acetylcysteine
- Saljoughian M., 2016, US Pharm, 41, 38
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
Sacks, D. B., Arnold, M. A., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad080 · Cited by 208
Li, J., Zhao, Y., & Shen, C. (2025) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2025.143842 · Cited by 17
Point of care blood glucose devices in the hospital setting
Tran, N. K., LaValley, C., Bagley, B., & Rodrigo, J. (2023) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2023.2170316 · Cited by 17
“) with certain GDH/PQQ-based biosensors [25], and medications such as N-acetylcysteine [27].”
BackgroundHauss, O., Hinzmann, R., & Huffman, B. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221140420 · Cited by 17
Metadata
- Authors
- Lyon, M. E., & Lyon, A. W.
- Affiliations
- Saskatchewan Health Authority (CA)
- Corresponding author
- Lyon, Andrew W.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2021-03-14
- Volume
- 16
- Issue
- 5
- Pages
- 1114-1119
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC9445331
- OpenAlex
- W3136585435
- Cited by
- 10
- References
- 12
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 1 · 2023: 5 · 2022: 1
- FWCI
- 1.10
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- N-acetylcysteine, blood glucose measurement, therapeutic drug concentrations, measurement bias, glucose oxidase, blood gas analyzer, point-of-care glucose testing
- MeSH terms
- Acetylcysteine, Blood Glucose, Glucose, Hematologic Tests, Humans, Glucose 1-Dehydrogenase
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: N-Acetylcysteine Interference with a Glucose Dehydrogenase Linked Glucose Meter. https://app.cochat.ai/papers/10.1177/1932296821999416
- The paper
- Lyon, M. E., & Lyon, A. W. (2022). N-Acetylcysteine Interference with a Glucose Dehydrogenase Linked Glucose Meter. Journal of Diabetes Science and Technology. https://doi.org/10.1177/1932296821999416
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.