The DOI matches its Crossref record.
Fast-scan cyclic voltammetry of 5-hydroxytryptamine
Abstract
Fast-scan cyclic voltammetry, a demonstrated analytical method for the in vivo detection of dopamine, is extended to the detection of in vitro and in vivo 5-hydroxytryptamine (5-HT) with the use of a specific potential wave form applied at 1000 V/s. The wave form, 0.2 to 1.0 to -0.1 to 0.2 V, is employed to accelerate electrode response times which are significantly slower with other wave forms due to the adsorption of 5-HT. The scan rate of 1000 V/s enables follow-up reactions which lead to the formation of strongly adsorptive products to be outrun. The peak current at a carbon fiber disk microelectrode exposed to 1 microM 5-HT in flow injection experiments is 1 nA, with a half-rise time of less than 200 ms. The peak current of Nafion-coated electrodes exposed to the same concentration of 5-HT is 5 nA, with a half-rise time on the order of 400 ms. The rate of adsorption of 5-HT was determined to be 4.22 +/- 0.33 s-1. Several compounds present in brain tissue as well as the pharmacological agents used to elicit 5-HT release in the caudate of the rat were evaluated. Those which gave a response could be differentiated from 5-HT on the basis of respective oxidative and reductive peak potentials. Nafion-coated electrodes were used to monitor transient increases in both dopamine and exogenous 5-HT in the caudate of the anesthetized rat in response to electrical stimulation. The rate of cellular uptake of 5-HT was shown to be 3-fold slower than dopamine uptake. NS-15841
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hersey, M., Woodruff, J. L., Maxwell, N., Sadek, A. T., Bykalo, M. K., Bain, I., Grillo, C. A., Piroli, G. G., Hashemi, P., & Reagan, L. P. (2021) · Brain Behavior and Immunity · doi:10.1016/j.bbi.2021.05.010 · Cited by 48
Serotonin is a common thread linking different classes of antidepressants
Witt, C. E., Mena, S., Holmes, J., Hersey, M., Buchanan, A. M., Parke, B., Saylor, R., Honan, L. E., Berger, S. N., Lumbreras, S., et al. (2023) · Cell Chemical Biology · doi:10.1016/j.chembiol.2023.10.009 · Cited by 18
Metadata
- Authors
- Jackson, B. P., Dietz, S. M., & Wightman, R. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1995-03-15
- Volume
- 67
- Issue
- 6
- Pages
- 1115-1120
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2079402691
- Cited by
- 268
- References
- 0
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fast-scan cyclic voltammetry of 5-hydroxytryptamine. https://app.cochat.ai/papers/10.1021/ac00102a015
- The paper
- Jackson, B. P., Dietz, S. M., & Wightman, R. M. (1995). Fast-scan cyclic voltammetry of 5-hydroxytryptamine. Analytical Chemistry. https://doi.org/10.1021/ac00102a015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.