The DOI matches its Crossref record.
Method to Correlate Tandem Mass Spectra of Modified Peptides to Amino Acid Sequences in the Protein Database
Abstract
A method to correlate uninterpreted tandem mass spectra of modified peptides, produced under low-energy (10-50 eV) collision conditions, with amino acid sequences in a protein database has been developed. The fragmentation patterns observed in the tandem mass spectra of peptides containing covalent modifications is used to directly search and fit linear amino acid sequences in the database. Specific information relevant to sites of modification is not contained in the character-based sequence information of the databases. The search method considers each putative modification site as both modified and unmodified in one pass through the database and simultaneously considers up to three different sites of modification. The search method will identify the correct sequence if the tandem mass spectrum did not represent a modified peptide. This approach is demonstrated with peptides containing modifications such as S-carboxymethylated cysteine, oxidized methionine, phosphoserine, phosphothreonine, or phosphotyrosine. In addition, a scanning approach is used in which neutral loss scans are used to initiate the acquisition of product ion MS/MS spectra of doubly charged phosphorylated peptides during a single chromatographic run for data analysis with the database-searching algorithm. The approach described in this paper provides a convenient method to match the nascent tandem mass spectra of modified peptides to sequences in a protein database and thereby identify previously unknown sites of modification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multi-omics approaches to disease
Hasin, Y., Seldin, M., & Lusis, A. (2017) · Genome Biology · doi:10.1186/s13059-017-1215-1 · Cited by 2,953
Lundqvist, M., Stigler, J., Elia, G., Lynch, I., Cedervall, T., & Dawson, K. A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0805135105 · Cited by 2,823
Gao, P., Tchernyshyov, I., Chang, T.-C., Lee, Y.-S., Kita, K., Ochi, T., Zeller, K. I., De Marzo, A. M., Van Eyk, J. E., Mendell, J. T., et al. (2009) · Nature · doi:10.1038/nature07823 · Cited by 2,124
The Evolution of the Protein Corona around Nanoparticles: A Test Study
Lundqvist, M., Stigler, J., Cedervall, T., Berggård, T., Flanagan, M. B., Lynch, I., Elia, G., & Dawson, K. (2011) · ACS Nano · doi:10.1021/nn202458g · Cited by 752
Lawrence, J. B., Oxvig, C., Overgaard, M. T., Sottrup-Jensen, L., Gleich, G. J., Hays, L. G., Yates, J. R., & Conover, C. A. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.6.3149 · Cited by 706
Self-citation
Metadata
- Authors
- Yates, J. R., Eng, J. K., McCormack, A. L., & Schieltz, D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1995-04-15
- Volume
- 67
- Issue
- 8
- Pages
- 1426-1436
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2059572899
- Cited by
- 1,253
- References
- 0
- FWCI
- 17.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Method to Correlate Tandem Mass Spectra of Modified Peptides to Amino Acid Sequences in the Protein Database. https://app.cochat.ai/papers/10.1021/ac00104a020
- The paper
- Yates, J. R., Eng, J. K., McCormack, A. L., & Schieltz, D. (1995). Method to Correlate Tandem Mass Spectra of Modified Peptides to Amino Acid Sequences in the Protein Database. Analytical Chemistry. https://doi.org/10.1021/ac00104a020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.