The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
High-Resolution Matrix-Assisted Laser Desorption/Ionization in a Linear Time-of-Flight Mass Spectrometer
Abstract
A time-lag focusing method is developed for the improvement of mass resolution in a linear time-of-flight mass spectrometer for matrix-assisted laser desorption/ionization (MALDI). In this technique, the ions generated by the MALDI process are extracted by a pulsed voltage. A short time delay (280 ns) is inserted in between the laser desorption/ionization event and the ion extraction. The region between the repeller and extraction grid is field-free during the delay. The time-lag extraction allows the ions generated in the region between the repeller and the extraction grid to separate according to their velocity (energy). Application, to the repeller, of the appropriate pulse voltage provides the energy correction necessary to simultaneously detect all ions of the same mass/charge regardless of their initial energy, resulting in improved mass resolution. It is demonstrated that mass resolution in the range of 3000-6000 fwhm can be obtained. With this mass resolution, isotopically resolved mass spectra are observed for peptides with masses up to 3000 Da. For proteins, such as bovine insulin, cytochrome c, and apomyoglobin, resolution in the range of 800-1000 fwhm is observed with a mass measurement accuracy better than 0.01%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Covey, T. R., Huang, E. C., & Henion, J. D. (1991) · Analytical Chemistry · doi:10.1021/ac00013a003 · Cited by 446
Cited by
Shevchenko, A., Jensen, O. N., Podtelejnikov, A. V., Sagliocco, F., Wilm, M., Vorm, O., Mortensen, P., Shevchenko, A., Boucherie, H., & Mann, M. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.25.14440 · Cited by 1,427
Delayed extraction matrix‐assisted laser desorption time‐of‐flight mass spectrometry
Vestal, M. L., Juhasz, P., & Martin, S. A. (1995) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290091115 · Cited by 497
Characterization of synthetic polymers by MALDI-MS
Montaudo, G., Samperi, F., & Montaudo, M. S. (2006) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2005.12.001 · Cited by 446
Mass spectrometry of nucleic acids
Nordhoff, E., Kirpekar, F., & Roepstorff, P. (1996) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1996)15:2<67::aid-mas1>3.0.co;2-8 · Cited by 315
Sample Preparation Methods for Mass Spectrometric Peptide Mapping Directly from 2-DE Gels
Jensen, O. N., Wilm, M., Shevchenko, A., & Mann, M. (2003) · 2-D Proteome Analysis Protocols · doi:10.1385/1-59259-584-7:513 · Cited by 305
Metadata
- Authors
- Whittal, R. M., & Li, L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1995-07-01
- Volume
- 67
- Issue
- 13
- Pages
- 1950-1954
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1965290366
- Cited by
- 172
- References
- 1
- FWCI
- 13.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.