Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 497

The DOI matches its Crossref record.

Delayed extraction matrix‐assisted laser desorption time‐of‐flight mass spectrometry

Vestal, M. L., Juhasz, P., Martin, S. A.·1995·Rapid Communications in Mass Spectrometry

Abstract

A new delayed extraction matrix‐assisted laser desorption/ionization (MALDI) time‐of‐flight (TOF) mass spectrometer system is described which provides dramatically improved performance over that obtained with identical TOF analyzers operated with constant electrical fields. In this system the ions formed by MALDI are produced in a weak electrical field, and subsequently extracted by application of a high voltage pulse after a predetermined time delay. Three parameters can be independently adjusted to optimize the performance. These include the field magnitude and direction during and immediately following ion production, the magnitude of the extraction field, and the time delay between the laser pulse and application of the extraction field. Theoretical equations are presented which guide the selection of these parameters to optimize the performance. Results are presented from three TOF analyzers of similar design, but ranging in size from a 1.3 m linear analyzer to a 6.4 m reflector. In all cases delayed extraction provides substantially improved resolution over that obtained from static operation. In the smallest linear analyzer resolution of M/ΔM (full width at half maximum) of 4000 is demonstrated for angiotensin I, and with the largest reflecting analyzer, the isotope peaks of bovine insulin are resolved nearly to baseline. With larger proteins, the isotopic peaks are not resolved, but resolution approaching the width of the isotopic envelope is obtained. Resolution improvement is demonstrated for proteins up to 30 kDa. In addition to improved resolution, delayed extraction is shown to improve the quality of MALDI mass spectra by suppressing matrix background, reducing chemical noise, and minimizing the effect of laser intensity on performance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.1290091115

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 497

Metadata

Authors
Vestal, M. L., Juhasz, P., & Martin, S. A.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
1995-01
Volume
9
Issue
11
Pages
1044-1050
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2135842532
Cited by
497
References
0
FWCI
32.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Delayed extraction matrix‐assisted laser desorption time‐of‐flight mass spectrometry. https://app.cochat.ai/papers/10.1002/rcm.1290091115
The paper
Vestal, M. L., Juhasz, P., & Martin, S. A. (1995). Delayed extraction matrix‐assisted laser desorption time‐of‐flight mass spectrometry. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.1290091115

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.