The DOI matches its Crossref record.
Sonic spray mass spectrometry
Abstract
We have developed a sonic spray ionization method, in which a methanol and water solution is sprayed from a fused-silica capillary with gas flow coaxial to the capillary. Ions as well as charged droplets are produced under atmospheric pressure, and their intensities depend on the gas flow rate (gas velocity). Positive ions produced from dilute solutions of molecules regarded as neurotransmitters, such as catecholamine, by this ionization method have been analyzed with a quadrupole mass spectrometer. The protonated dopamine molecule is detected in the spray of the 10 nM solution, and the mass spectrum is compared with that obtained by the ion spray ionization method. A comparison between the mass-analyzed ion intensity and the ion current, which represents the sum of ions and charged droplets, shows that most ions are produced from the charged droplets after spraying. Furthermore, we found that the charged droplet formation cannot be ascribed to the traditional models of friction electrification, electrical double layer, or statistical charging. An explanation is proposed based on the ion concentration distribution in a small droplet.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ambient mass spectrometry: bringing MS into the “real world”
Alberici, R. M., Simas, R. C., Sanvido, G. B., Romão, W., Lalli, P. M., Benassi, M., Cunha, I. B. S., & Eberlin, M. N. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3808-3 · Cited by 340
Van Berkel, G. J., Pasilis, S. P., & Ovchinnikova, O. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1440 · Cited by 299
Serine Octamers: Cluster Formation, Reactions, and Implications for Biomolecule Homochirality
Nanita, S. C., & Cooks, R. G. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200501328 · Cited by 184
Serine Octamer Reactions: Indicators of Prebiotic Relevance
Takats, Z., Nanita, S. C., & Cooks, R. G. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200351210 · Cited by 107
Enrichment Factors of Perfluoroalkyl Oxoanions at the Air/Water Interface
Psillakis, E., Cheng, J., Hoffmann, M. R., & Colussi, A. J. (2009) · The Journal of Physical Chemistry A · doi:10.1021/jp902795m · Cited by 64
Metadata
- Authors
- Hirabayashi, A., Sakairi, M., & Koizumi, H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1995-09-01
- Volume
- 67
- Issue
- 17
- Pages
- 2878-2882
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2065649159
- Cited by
- 224
- References
- 0
- FWCI
- 1.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sonic spray mass spectrometry. https://app.cochat.ai/papers/10.1021/ac00113a023
- The paper
- Hirabayashi, A., Sakairi, M., & Koizumi, H. (1995). Sonic spray mass spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac00113a023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.