The DOI matches its Crossref record.
Fourier Transform Spectroscopic Imaging Using an Infrared Focal-Plane Array Detector
Abstract
A powerful new mid-infrared spectroscopic chemical imaging technique combining step-scan Fourier transform Michelson interferometry with indium antimonide focal-plane array (FPA) image detection is described. The coupling of an infrared focal-plane array detector to an interferometer provides an instrumental multiplex/multichannel advantage. Specifically, the multiple detector elements enable spectra at all pixels to be collected simultaneously, while the interferometer portion of the system allows all the spectral frequencies to be measured concurrently. With this method of mid-infrared spectroscopic imaging, the fidelity of the generated spectral images is limited only by the number of pixels on the FPA detector, and only several seconds of starting time is required for spectral image acquisition. This novel, high-definition technique represents the future of infrared chemical imaging analysis, a new discipline within the chemical and material sciences, which combines the capability of spectroscopy for molecular analysis with the power of visualization. In particular, chemical imaging is broadly applicable for noninvasive, molecular characterization of heterogeneous materials, since all solid-state materials exhibit chemical nonuniformity that exists either by design or by development during the course of material preparation or fabrication. Imaging, employing Raman and infrared spectroscopy, allows the precise characterization of the chemical composition, domain structure, and chemical architecture of a variety of substances. This information is often crucial to a wide range of activities, extending from the fabrication of new materials to a basic understanding of biological samples. In this study, step-scan imaging principles, instrument design details, and infrared chemical imaging results are presented. Since the prospect of performing high-resolution and high-definition mid-infrared chemical imaging very rapidly has been achieved with the step-scan approach, the implications for the chemical analysis of materials are many and varied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wu, C., Khanikaev, A. B., Adato, R., Arju, N., Yanik, A. A., Altug, H., & Shvets, G. (2012) · Nature Materials · doi:10.1038/nmat3161 · Cited by 1,045
Prospects for in vivo Raman spectroscopy
Hanlon, E. B., Manoharan, R., Koo, T.-W., Shafer, K. E., Motz, J. T., Fitzmaurice, M., Kramer, J. R., Itzkan, I., Dasari, R. R., & Feld, M. S. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/201 · Cited by 894
Infrared spectroscopic imaging for histopathologic recognition
Fernandez, D. C., Bhargava, R., Hewitt, S. M., & Levin, I. W. (2005) · Nature Biotechnology · doi:10.1038/nbt1080 · Cited by 592
Self-citationFT-IR imaging of native and tissue-engineered bone and cartilage
Boskey, A., & Pleshko Camacho, N. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.043 · Cited by 531
Dobson, R. L. M., Motlagh, S., Quijano, M., Cambron, R. T., Baker, T. R., Pullen, A. M., Regg, B. T., Bigalow-Kern, A. S., Vennard, T., Fix, A., et al. (2008) · Toxicological Sciences · doi:10.1093/toxsci/kfn160 · Cited by 458
Zhang, D., Li, C., Zhang, C., Slipchenko, M. N., Eakins, G., & Cheng, J.-X. (2016) · Science Advances · doi:10.1126/sciadv.1600521 · Cited by 389
Chemical imaging of biological tissue with synchrotron infrared light
Miller, L. M., & Dumas, P. (2006) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2006.04.010 · Cited by 385
Applications of ATR-FTIR spectroscopic imaging to biomedical samples
Kazarian, S. G., & Chan, K. L. A. (2006) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2006.02.011 · Cited by 379
High-resolution Fourier-transform infrared chemical imaging with multiple synchrotron beams
Nasse, M. J., Walsh, M. J., Mattson, E. C., Reininger, R., Kajdacsy-Balla, A., Macias, V., Bhargava, R., & Hirschmugl, C. J. (2011) · Nature Methods · doi:10.1038/nmeth.1585 · Cited by 349
Levin, I. W., & Bhargava, R. (2005) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.56.092503.141205 · Cited by 300
Self-citationInfrared Spectroscopic Imaging: The Next Generation
Bhargava, R. (2012) · Applied Spectroscopy · doi:10.1366/12-06801 · Cited by 280
Osteoblast-Mediated Mineral Deposition in Culture is Dependent on Surface Microtopography
Boyan, B. D., Bonewald, L. F., Paschalis, E. P., Lohmann, C. H., Rosser, J., Cochran, D. L., Dean, D. D., Schwartz, Z., & Boskey, A. L. (2002) · Calcified Tissue International · doi:10.1007/s00223-001-1114-y · Cited by 256
Theory of Midinfrared Absorption Microspectroscopy: I. Homogeneous Samples
Davis, B. J., Carney, P. S., & Bhargava, R. (2010) · Analytical Chemistry · doi:10.1021/ac902067p · Cited by 115
Osman, O. B., & Arbab, M. H. (2019) · PLOS ONE · doi:10.1371/journal.pone.0216952 · Cited by 27
Metadata
- Authors
- Lewis, E. N., Treado, P. J., Reeder, R. C., Story, G. M., Dowrey, A. E., Marcott, C., & Levin, I. W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1995-10-01
- Volume
- 67
- Issue
- 19
- Pages
- 3377-3381
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2034901710
- Cited by
- 439
- References
- 0
- FWCI
- 7.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.