Limitations to the Use of Solid-Phase Microextraction for Quantitation of Mixtures of Volatile Organic Sulfur Compounds
The DOI matches its Crossref record.
Abstract
A study of the range of volatile organic sulfur compounds produced by brassica plants has highlighted limitations to the use of Carboxen/PDMS fibers for their analysis by solid-phase microextraction (SPME). These fibers are sometimes advocated for the analysis of sulfur gases, but a quantitative comparison of analytical data derived by SPME and by direct gas sampling of standard mixtures of volatile low molecular weight sulfur compounds at 0.01-10 mg/L has identified potential errors associated with their use. Higher molecular compounds displace lower molecular weight compounds as a consequence of competition for active sites on the fiber, and the relative proportions of the components adsorbed onto the fiber depend on their ratio in the headspace. As their relative concentrations change from sample to sample, the varying interactions result in irregular analytical responses, reflected in erratic calibration curves. Standards containing single components are not valid; only a standard containing all components found in the sample to be analyzed, and at the same relative concentrations, is appropriate. In practice, this may preclude the use of the fibers for quantitative analysis of multicomponent mixtures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Amann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Bentley, R., & Chasteen, T. G. (2004) · Chemosphere · doi:10.1016/j.chemosphere.2003.12.017 · Cited by 292
Diez-Simon, C., Mumm, R., & Hall, R. D. (2019) · Metabolomics · doi:10.1007/s11306-019-1493-6 · Cited by 248
“However, some researchers report limitations on the use of SPME if quantification is desired (Murray 2001).”
BackgroundPinho, O., Ferreira, I. M. P. L. V. O., & Santos, L. H. M. L. M. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.04.013 · Cited by 127
Human body-odor components and their determination
Pandey, S. K., & Kim, K.-H. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.12.005 · Cited by 121
Metadata
- Authors
- Murray, R. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-02-22
- Volume
- 73
- Issue
- 7
- Pages
- 1646-1649
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1988419866
- Cited by
- 113
- References
- 0
- FWCI
- 6.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Limitations to the Use of Solid-Phase Microextraction for Quantitation of Mixtures of Volatile Organic Sulfur Compounds. https://app.cochat.ai/papers/10.1021/ac001176m
- The paper
- Murray, R. A. (2001). Limitations to the Use of Solid-Phase Microextraction for Quantitation of Mixtures of Volatile Organic Sulfur Compounds. Analytical Chemistry. https://doi.org/10.1021/ac001176m
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.