The human volatilome: volatile organic compounds (VOCs) in exhaled breath, skin emanations, urine, feces and saliva
Abstract
Breath analysis is a young field of research with its roots in antiquity. Antoine Lavoisier discovered carbon dioxide in exhaled breath during the period 1777-1783, Wilhelm (Vilém) Petters discovered acetone in breath in 1857 and Johannes Müller reported the first quantitative measurements of acetone in 1898. A recent review reported 1765 volatile compounds appearing in exhaled breath, skin emanations, urine, saliva, human breast milk, blood and feces. For a large number of compounds, real-time analysis of exhaled breath or skin emanations has been performed, e.g., during exertion of effort on a stationary bicycle or during sleep. Volatile compounds in exhaled breath, which record historical exposure, are called the 'exposome'. Changes in biogenic volatile organic compound concentrations can be used to mirror metabolic or (patho)physiological processes in the whole body or blood concentrations of drugs (e.g. propofol) in clinical settings-even during artificial ventilation or during surgery. Also compounds released by bacterial strains like Pseudomonas aeruginosa or Streptococcus pneumonia could be very interesting. Methyl methacrylate (CAS 80-62-6), for example, was observed in the headspace of Streptococcus pneumonia in concentrations up to 1420 ppb. Fecal volatiles have been implicated in differentiating certain infectious bowel diseases such as Clostridium difficile, Campylobacter, Salmonella and Cholera. They have also been used to differentiate other non-infectious conditions such as irritable bowel syndrome and inflammatory bowel disease. In addition, alterations in urine volatiles have been used to detect urinary tract infections, bladder, prostate and other cancers. Peroxidation of lipids and other biomolecules by reactive oxygen species produce volatile compounds like ethane and 1-pentane. Noninvasive detection and therapeutic monitoring of oxidative stress would be highly desirable in autoimmunological, neurological, inflammatory diseases and cancer, but also during surgery and in intensive care units. The investigation of cell cultures opens up new possibilities for elucidation of the biochemical background of volatile compounds. In future studies, combined investigations of a particular compound with regard to human matrices such as breath, urine, saliva and cell culture investigations will lead to novel scientific progress in the field.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Monitoring and analyzing exhaled breath (respiratory rate and composition) can achieve non-invasive early prevention and treatment of certain diseases.
“monitoring and analyzing information related to it, such as respiratory rate and composition of exhalation, can achieve the non-invasive and comfortable early prevention and treatment of certain diseases”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as [22]
Cites
Puzzlingly High Correlations in fMRI Studies of Emotion, Personality, and Social Cognition
Vul, E., Harris, C., Winkielman, P., & Pashler, H. (2009) · Perspectives on Psychological Science · doi:10.1111/j.1745-6924.2009.01125.x · Cited by 1,475 · see citing works
Kaufman, E., & Lamster, I. B. (2002) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/154411130201300209 · Cited by 887 · see citing works
Pimentel, M., Lin, H. C., Enayati, P., van den Burg, B., Lee, H.-R., Chen, J. H., Park, S., Kong, Y., & Conklin, J. (2006) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.00574.2004 · Cited by 508 · see citing works
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Specialized metabolites from the microbiome in health and disease
Sharon, G., Garg, N., Debelius, J., Knight, R., Dorrestein, P. C., & Mazmanian, S. K. (2014) · Cell Metabolism · doi:10.1016/j.cmet.2014.10.016 · Cited by 544 · see citing works
Prospects and Challenges of Volatile Organic Compound Sensors in Human Healthcare
Jalal, A. H., Alam, F., Roychoudhury, S., Umasankar, Y., Pala, N., & Bhansali, S. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00400 · Cited by 315 · see citing works
Perge, J. A., Homer, M. L., Malik, W. Q., Cash, S., Eskandar, E., Friehs, G., Donoghue, J. P., & Hochberg, L. R. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036004 · Cited by 243 · see citing works
Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors.
Luo, Y., Li, J., Ding, Q., Wang, H., Liu, C., & Wu, J. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01109-2 · Cited by 236 · see citing works
“As human exhalation contains a large number of gas and water molecules, monitoring and analyzing information related to it, such as respiratory rate and composition of exhalation, can achieve the non-invasive and comfortable early prevention and treatment of certain diseases [21, 22].”
BackgroundNanoscale RRAM-based synaptic electronics: toward a neuromorphic computing device
Park, S., Noh, J., Choo, M.-L., Sheri, A. M., Chang, M., Kim, Y.-B., Kim, C. J., Jeon, M., Lee, B.-G., Lee, B. H., et al. (2013) · Nanotechnology · doi:10.1088/0957-4484/24/38/384009 · Cited by 139 · see citing works
Investigations of sensitivity and resolution of ECG and MCG in a realistically shaped thorax model
Mäntynen, V., Konttila, T., & Stenroos, M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/23/7141 · Cited by 45 · see citing works
Peel, A. M., Wilkinson, M., Sinha, A., Loke, Y. K., Fowler, S. J., & Wilson, A. M. (2020) · Respiratory Medicine · doi:10.1016/j.rmed.2020.105984 · Cited by 40 · see citing works
Raninen, K., Lappi, J., Kolehmainen, M., Kolehmainen, M., Mykkänen, H., Poutanen, K., & Raatikainen, O. (2017) · International Journal of Food Sciences and Nutrition · doi:10.1080/09637486.2017.1312296 · Cited by 15 · see citing works
- Authors
- Amann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T.
- Affiliations
- Innsbruck Medical University (AT)
- University of the West of England (GB)
- University of Rostock (DE)
- Nicolaus Copernicus University (PL)
- Environmental Protection Agency (US)
- Johns Hopkins University (US)
- ORCID
- Venue
- Journal of Breath Research
- Publisher
- IOP Publishing
- Published
- 2014-06-19
- Volume
- 8
- Issue
- 3
- Pages
- 034001
- ISSN
- 1752-7155 (ISSN-L)
- 1752-7163
- OpenAlex
- W2059982453
- Cited by
- 804
- References
- 4
- Citations by year
- 2026: 69 · 2025: 73 · 2024: 75 · 2023: 77 · 2022: 91 · 2021: 87 · 2020: 66 · 2019: 58 · 2018: 61 · 2017: 44 · 2016: 29 · 2015: 34 · 2014: 26 · 2013: 14
- FWCI
- 3.81
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Journal of Breath Research (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Österreichische Forschungsförderungsgesellschaft
- Bundesministerium für Verkehr, Innovation und Technologie
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
- Physical Sciences › Chemical Engineering › Process Chemistry and Technology › Odor and Emission Control Technologies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- volatile organic compounds, exhaled breath, saliva, exposome, bacterial volatile compounds, Streptococcus pneumoniae, methyl methacrylate, Clostridium difficile, irritable bowel syndrome, inflammatory bowel disease, urinary tract infection, cancer detection, oxidative stress biomarkers, lipid peroxidation, non-invasive monitoring
- MeSH terms
- Breath Tests, Feces, Humans, Saliva, Skin, Exhalation, Volatile Organic Compounds
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review