A CE−MALDI Interface Based on the Use of Prestructured Sample Supports
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We have developed an off-line coupling of capillary electrophoresis (CE) to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry(MALDI-TOF-MS) based on CE fraction collection onto prestructured MALDI sample supports. Analyte carryover and detection sensitivity were investigated using a standard peptide mixture. Low femtomole amounts were detected, and no noticeable carryover was discovered. The performance of the method was evaluated with a mixture of tryptic digests of proteins from a human fetal brain cDNA expression library. The total number of identified peptides was increased from 47 to 211 when the CE-MALDI interface was used compared to direct MALDI-MS analysis. Sequence coverage with CE-MALDI was in the 25-60% range for the different proteins, corresponding to an increase of 1.3-4.9 times relative to that obtained with MALDI-MS of the crude mixture. Fractionation of sample components also facilitated protein identification by MALDI postsource decay analysis. Our initial results suggest this CE-MALDI interface can be used for the analysis of complex peptide mixtures isolated from biological tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Cited by
Surface plasmon resonance: principles, methods and applications in biomedical sciences
Englebienne, P., Hoonacker, A. V., & Verhas, M. (2003) · Journal of Spectroscopy · doi:10.1155/2003/372913 · Cited by 348
Kolch, W., Neusüß, C., Pelzing, M., & Mischak, H. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20051 · Cited by 290
Capillary electrophoresis – mass spectrometry: 15 years of developments and applications
Schmitt‐Kopplin, P., & Frommberger, M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305659 · Cited by 289
Krokhin, O. V., Craig, R., Spicer, V., Ens, W., Standing, K. G., Beavis, R. C., & Wilkins, J. A. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400031-mcp200 · Cited by 284
“archive (14) samples in conjunction with advanced MALDI MS”
MethodWojcik, R., Dada, O. O., Sadilek, M., & Dovichi, N. J. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4672 · Cited by 234
Metadata
- Authors
- Johnson, T., Bergquist, J., Ekman, R., Nordhoff, E., Schürenberg, M., Klöppel, K.-D., Müller, M., Lehrach, H., & Gobom, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-03-09
- Volume
- 73
- Issue
- 8
- Pages
- 1670-1675
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2071758941
- Cited by
- 73
- References
- 1
- FWCI
- 3.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A CE−MALDI Interface Based on the Use of Prestructured Sample Supports. https://app.cochat.ai/papers/10.1021/ac0011888
- The paper
- Johnson, T., Bergquist, J., Ekman, R., Nordhoff, E., Schürenberg, M., Klöppel, K.-D., Müller, M., Lehrach, H., & Gobom, J. (2001). A CE−MALDI Interface Based on the Use of Prestructured Sample Supports. Analytical Chemistry. https://doi.org/10.1021/ac0011888
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.