The DOI matches its Crossref record.
Protein Sizing on a Microchip
Abstract
We have developed a microfabricated analytical device on a glass chip that performs a protein sizing assay, by integrating the required separation, staining, virtual destaining, and detection steps. To obtain a universal noncovalent fluorescent labeling method, we have combined on-chip dye staining with a novel electrophoretic dilution step. Denatured protein-sodium dodecyl sulfate (SDS) complexes are loaded on a chip and bind a fluorescent dye as the separation begins. At the end of the separation channel, an intersection is used to dilute the SDS below its critical micelle concentration before the detection point. This strongly reduces the background due to dye molecules bound to SDS micelles and also increases the peak amplitude by 1 order of magnitude. Both the on-chip staining and SDS dilution steps occur in the 100-ms time scale and are approximately 10(4) times faster than their conventional counterparts in SDS-PAGE. This represents a much greater speed increase due to microfabrication than has been obtained in other assay steps such as electrophoretic separations. We have designed and tested a microchip capable of sequentially analyzing 11 different samples, with sizing accuracy better than 5% and high sensitivity (30 nM for carbonic anhydrase).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Micro Total Analysis Systems. 2. Analytical Standard Operations and Applications
Auroux, P.-A., Iossifidis, D., Reyes, D. R., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac020239t · Cited by 1,532
Microfluidic chips for clinical and forensic analysis
Verpoorte, E. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200203)23:5<677::aid-elps677>3.0.co;2-8 · Cited by 526
Grover, W. H., Skelley, A. M., Liu, C. N., Lagally, E. T., & Mathies, R. A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00468-9 · Cited by 517
Lab-on-a-chip for drug development
Weigl, B. H., Bardell, R. L., & Cabrera, C. R. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00223-5 · Cited by 481
Microfluidic systems in proteomics
Lion, N., Rohner, T. C., Dayon, L., Arnaud, I. L., Damoc, E., Youhnovski, N., Wu, Z., Roussel, C., Josserand, J., Jensen, H., et al. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305629 · Cited by 262
Metadata
- Authors
- Bousse, L., Mouradian, S., Minalla, A., Yee, H., Williams, K., & Dubrow, R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-02-08
- Volume
- 73
- Issue
- 6
- Pages
- 1207-1212
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1968960019
- Cited by
- 283
- References
- 0
- FWCI
- 21.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Protein Sizing on a Microchip. https://app.cochat.ai/papers/10.1021/ac0012492
- The paper
- Bousse, L., Mouradian, S., Minalla, A., Yee, H., Williams, K., & Dubrow, R. (2001). Protein Sizing on a Microchip. Analytical Chemistry. https://doi.org/10.1021/ac0012492
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.