The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Supercharged Protein and Peptide Ions Formed by Electrospray Ionization
Open accessAbstract
The multiple charging of large molecules in electrospray ionization provides key advantages for obtaining accurate molecular weights by mass spectrometry and for obtaining structural information by tandem mass spectrometry and MS(n) experiments. Addition of glycerol or m-nitrobenzyl alcohol into the electrospray solutions dramatically increases both the maximum observed charge state and the abundances of the high charge states of protein and peptide ions. Adding glycerol to acidified aqueous solutions of cytochrome c shifts the most abundant charge state from 17+ to 21+, shifts the maximum charge state from 20+ to 23+, and shifts the average charge state from 16.6+ to 20.9+. Much less m-nitrobenzyl alcohol (<1%) is required to produce similar results. With just 0.7% m-nitrobenzyl alcohol, even the 24+ charge state of cytochrome c is readily observed. Similar results are obtained with myoglobin and (Lys)4. For the latter molecule, the 5+ charge state is observed in the electrospray mass spectrum obtained from solutions containing 6.7% m-nitrobenzyl alcohol. This charge state corresponds to protonation of all basic sites in this peptide. Although the mechanism for enhanced charging is unclear, it does not appear to be a consequence of conformational changes of the analyte molecules. This method of producing highly charged protein ions should be useful for improving the performance of mass measurements on mass spectrometers with performances that decrease with increasing m/z. This should also be particularly useful for tandem mass spectrometry experiments, such as electron capture dissociation, for which highly charged ions are desired.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Cited by
Proteomics by FTICR mass spectrometry: Top down and bottom up
Bogdanov, B., & Smith, R. D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20015 · Cited by 447
Mechanism of Charging and Supercharging Molecules in Electrospray Ionization
Iavarone, A. T., & Williams, E. R. (2003) · Journal of the American Chemical Society · doi:10.1021/ja021202t · Cited by 324
Self-citationOn the Scalability and Requirements of Whole Protein Mass Spectrometry
Compton, P. D., Zamdborg, L., Thomas, P. M., & Kelleher, N. L. (2011) · Analytical Chemistry · doi:10.1021/ac2010795 · Cited by 243
Metadata
- Authors
- Iavarone, A. T., Jurchen, J. C., & Williams, E. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-03-03
- Volume
- 73
- Issue
- 7
- Pages
- 1455-1460
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1979627609
- Cited by
- 229
- References
- 2
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Supercharged Protein and Peptide Ions Formed by Electrospray Ionization. https://app.cochat.ai/papers/10.1021/ac001251t
- The paper
- Iavarone, A. T., Jurchen, J. C., & Williams, E. R. (2001). Supercharged Protein and Peptide Ions Formed by Electrospray Ionization. Analytical Chemistry. https://doi.org/10.1021/ac001251t
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.