Cited by 243Mass Spectrometry Techniques and ApplicationsAdvanced Proteomics Techniques and ApplicationsMetabolomics and Mass Spectrometry Studies

On the Scalability and Requirements of Whole Protein Mass Spectrometry

Open access
Compton, Philip D., Zamdborg, Leonid, Thomas, Paul M., Kelleher, Neil L.·2011·Analytical Chemistry

Abstract

Top-down proteomics has improved over the past decade despite the significant challenges presented by the analysis of large protein ions. Here, the detection of these high mass species by electrospray-based mass spectrometry (MS) is examined from a theoretical perspective to understand the mass-dependent increases in the number of charge states, isotopic peaks, and interfering species present in typical protein mass spectra. Integrating these effects into a quantitative model captures the reduced ability to detect species over 25 kDa with the speed and sensitivity characteristic of proteomics based on <3 kDa peptide ions. The model quantifies the challenge that top-down proteomics faces with respect to current MS instrumentation and projects that depletion of (13)C and (15)N isotopes can improve detection at high mass by only <2-fold at 100 kDa whereas the effect is up to 5-fold at 10 kDa. Further, we find that supercharging electrosprayed proteins to the point of producing <5 charge states at high mass would improve detection by more than 20-fold.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac2010795

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Large proteins have inherently lower signal-to-noise and are underrepresented in top-down studies.

    “Often large proteins, which have an inherently lower signal-to-noise, are underrepresented in top-down studies [83].”
  • ESI protein detection suffers from signal competition with small-molecule contaminants that outcompete large molecules, resulting in the need for highly purified samples.

    “Although ESI enables the highly sensitive detection of analytes, protein detection by ESI suffers from signal competition with small-molecule contaminates that outcompete large molecules and results in the need for highly purified samples [23,83].”
  • It remains challenging to detect and quantify large heart proteins such as cMyBP-C (141 kDa) and MHC (223 kDa) because of the exponential decay in MS signal-to-noise ratio observed with increasing molecular weight, combined with coelution of low-molecular-weight or high-abundance proteins.

    “It remains challenging to detect and quantify large heart proteins, such as cMyBP-C (141 kDa) (37, 44, 45) and MHC (223 kDa), because of the exponential decay in MS signal-to-noise ratio observed with the increasing molecular weight (46), combined with coelution of low-molecular-weight or high-abundance proteins.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 4

  1. [16]Hofstadler SA Bruce JE Rockwood AL Anderson GA Winger BE Smith RD International Journal of Mass Spectrometry 1994 132 109 127
  2. [21]Marshall AG Senko MW Li WQ Li M Dillon S Guan SH Logan TM Journal of the American Chemical Society 1997 119 433 434
  3. [33]Counterman AE Hilderbrand AE Barnes CAS Clemmer DE Journal of the American Society for Mass Spectrometry 2001 12 1020 1035
  4. [34]Lightwahl KJ Schwartz BL Smith RD Journal of the American Chemical Society 1994 116 5271 5278

Cited by

Sorted by citations

Authors
Compton, P. D., Zamdborg, L., Thomas, P. M., & Kelleher, N. L.
Affiliations
Northwestern University (US)
Corresponding author
Kelleher, Neil L.
Venue
Analytical Chemistry
Published
2011-07-29
Volume
83
Issue
17
Pages
6868-6874
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2010033716
Cited by
243
References
36
Citations by year
2026: 14 · 2025: 20 · 2024: 27 · 2023: 21 · 2022: 18 · 2021: 11 · 2020: 22 · 2019: 16 · 2018: 17 · 2017: 17 · 2016: 18 · 2015: 7 · 2014: 12 · 2013: 10 · 2012: 9
FWCI
5.08
Type
journal article
Language
en
Open access
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Institute on Drug Abuse (DA026672, F30DA026672, P30DA018310)
  • National Institute of General Medical Sciences (GM067193-09, R01GM067193)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
Keywords
top-down proteomics, electrospray ionization, charge state distribution, isotope depletion, supercharging, detection sensitivity, scalability
MeSH terms
Carbon Isotopes, Isotope Labeling, Nitrogen Isotopes, Proteins, Spectrometry, Mass, Electrospray Ionization, Proteomics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review