The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Polymeric Microfluidic Chip for CE/MS Determination of Small Molecules
Abstract
A polymeric microfluidic chip made of Zeonor 1020 was fabricated using conventional embossing techniques to perform capillary electrophoresis for selected ion monitoring and selected reaction monitoring mass spectrometric detection of small molecules. A silicon master was microfabricated using photolithographic and dry etching processes. The microfluidic channel was embossed in the plastic from a silicon master. The embossed chip was thermally bonded with a Zeonor 1020 cover to form an enclosed channel. This channel (60-microm width, 20-microm depth, 2.0- and 3.5-cm length) provided capillary electrophoresis (CE) separation of polar small molecules without surface treatment of the polymer. A microsprayer coupled via a microliquid junction provided direct electrospray mass spectrometric detection of CE-separated components. An electric field of 0.5-2 kV/cm applied between the microsprayer and a separation buffer reservoir produced a separation of carnitine, acylcarnitine, and butylcarnitine with separation efficiencies ranging from 1,650 to 18,000 plates. Injection quantities of 0.2 nmol of these compounds produced a separation of the targeted polar small molecules without surface treatment of the polymer-abundant ion current signals and baseline separation of these compounds in less than 10 s. These results suggest the feasibility of polymeric chip-based devices for ion spray CE/MS applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carnitine—metabolism and functions
Bremer, J. (1983) · Physiological Reviews · doi:10.1152/physrev.1983.63.4.1420 · Cited by 1,666
Cited by
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Abgrall, P., & Gué, A.-M. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/5/r01 · Cited by 561
Microfluidic chips for clinical and forensic analysis
Verpoorte, E. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200203)23:5<677::aid-elps677>3.0.co;2-8 · Cited by 526
Disposable Microfluidic Devices: Fabrication, Function, and Application
Fiorini, G. S., & Chiu, D. T. (2005) · BioTechniques · doi:10.2144/05383rv02 · Cited by 487
Lab-on-a-chip for drug development
Weigl, B. H., Bardell, R. L., & Cabrera, C. R. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00223-5 · Cited by 481
Metadata
- Authors
- Kameoka, J., Craighead, H. G., Zhang, H., & Henion, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-04-04
- Volume
- 73
- Issue
- 9
- Pages
- 1935-1941
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2043458312
- Cited by
- 224
- References
- 1
- FWCI
- 16.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Polymeric Microfluidic Chip for CE/MS Determination of Small Molecules. https://app.cochat.ai/papers/10.1021/ac001533t
- The paper
- Kameoka, J., Craighead, H. G., Zhang, H., & Henion, J. (2001). A Polymeric Microfluidic Chip for CE/MS Determination of Small Molecules. Analytical Chemistry. https://doi.org/10.1021/ac001533t
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.