The DOI matches its Crossref record.
Electrokinetically Driven Microfluidic Chips with Surface-Modified Chambers for Heterogeneous Immunoassays
Open accessAbstract
This article presents the first example of a microfluidic chip for heterogeneous bioassays using a locally immobilized biospecific layer and operated electrokinetically. The reaction chamber has picoliter dimensions and is integrated into a network of microchannels etched in glass. The high affinity of protein A (PA) for rabbit immunoglobulin G (rIgG) was exploited for chip testing, with PA being immobilized on microchannel walls and fluorescently labeled (Cy5) rIgG serving as sample. It was possible to operate the chip in an immunoaffinity chromatographic manner, using electrokinetically pumped solutions. Concentration of antibody from dilute solution onto the solid phase was demonstrated, with signal gains of approximately 30 possible. A dose-response curve for Cy5-rIgG was obtained for concentrations down to 50 nM, for an incubation time of 200 s. The flexibility of chip layout was demonstrated for competitive immunoassay of rIgG, using both a combined sample/tracer incubation and sequential addition of these solutions. With assay times generally below 5 min for this unoptimized device, the microfluidic approach described shows great potential for many high-throughput screening applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Micro Total Analysis Systems. 2. Analytical Standard Operations and Applications
Auroux, P.-A., Iossifidis, D., Reyes, D. R., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac020239t · Cited by 1,532
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Microfluidic chips for clinical and forensic analysis
Verpoorte, E. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200203)23:5<677::aid-elps677>3.0.co;2-8 · Cited by 526
Self-citationVerpoorte, E., & De Rooij, N. F. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813570 · Cited by 503
Self-citationLab-on-a-chip for drug development
Weigl, B. H., Bardell, R. L., & Cabrera, C. R. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00223-5 · Cited by 481
Microfluidic systems in proteomics
Lion, N., Rohner, T. C., Dayon, L., Arnaud, I. L., Damoc, E., Youhnovski, N., Wu, Z., Roussel, C., Josserand, J., Jensen, H., et al. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305629 · Cited by 262
Metadata
- Authors
- Dodge, A., Fluri, K., Verpoorte, E., & de Rooij, N. F.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-06-05
- Volume
- 73
- Issue
- 14
- Pages
- 3400-3409
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1985800449
- Cited by
- 199
- References
- 0
- FWCI
- 23.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.