The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Analytical and micropreparative ultrahigh resolution of oligonucleotides by polyacrylamide gel high-performance capillary electrophoresis
Abstract
ADVERTISEMENT RETURN TO ISSUEPREVArticleNEXTAnalytical and micropreparative ultrahigh resolution of oligonucleotides by polyacrylamide gel high-performance capillary electrophoresisA. Guttman, A. S. Cohen, D. N. Heiger, and Barry L. KargerCite this: Anal. Chem. 1990, 62, 2, 137–141Publication Date (Print):January 15, 1990Publication History Published online1 May 2002Published inissue 15 January 1990https://pubs.acs.org/doi/10.1021/ac00201a010https://doi.org/10.1021/ac00201a010research-articleACS PublicationsRequest reuse permissionsArticle Views356Altmetric-Citations218LEARN ABOUT THESE METRICSArticle Views are the COUNTER-compliant sum of full text article downloads since November 2008 (both PDF and HTML) across all institutions and individuals. These metrics are regularly updated to reflect usage leading up to the last few days.Citations are the number of other articles citing this article, calculated by Crossref and updated daily. Find more information about Crossref citation counts.The Altmetric Attention Score is a quantitative measure of the attention that a research article has received online. Clicking on the donut icon will load a page at altmetric.com with additional details about the score and the social media presence for the given article. Find more information on the Altmetric Attention Score and how the score is calculated. Share Add toView InAdd Full Text with ReferenceAdd Description ExportRISCitationCitation and abstractCitation and referencesMore Options Share onFacebookTwitterWechatLinked InRedditEmail Other access optionsGet e-Alertsclose Get e-Alerts
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescence detection in automated DNA sequence analysis
Smith, L. M., Sanders, J. Z., Kaiser, R. J., Hughes, P., Dodd, C., Connell, C. R., Heiner, C., Kent, S. B. H., & Hood, L. E. (1986) · Nature · doi:10.1038/321674a0 · Cited by 1,714
Capillary Zone Electrophoresis
Jorgenson, J. W., & Lukacs, K. D. (1983) · Science · doi:10.1126/science.6623076 · Cited by 1,289
Equations for calculation of chromatographic figures of merit for ideal and skewed peaks
Foley, J. P., & Dorsey, J. G. (1983) · Analytical Chemistry · doi:10.1021/ac00255a033 · Cited by 631
Capillary zone electrophoresis of proteins in untreated fused silica tubing
Lauer, H. H., & McManigill, D. (1986) · Analytical Chemistry · doi:10.1021/ac00292a041 · Cited by 616
Cohen, A. S., & Karger, B. L. (1987) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)85026-3 · Cited by 378
Self-citationCohen, A. S., Najarian, D. R., Paulus, A., Guttman, A., Smith, J. A., & Karger, B. L. (1988) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.85.24.9660 · Cited by 318
Self-citationHigh-performance capillary electrophoresis in the biological sciences
Karger, B. L., Cohen, A. S., & Guttman, A. (1989) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)84480-1 · Cited by 316
Self-citationPulsed-Field Gel Electrophoresis of Very Large DNA Molecules
Cantor, C. R., Smith, C. L., & Mathew, M. K. (1988) · Annual Review of Biophysics and Biophysical Chemistry · doi:10.1146/annurev.bb.17.060188.001443 · Cited by 196
Nelson, R. J., Paulus, A., Cohen, A. S., Guttman, A., & Karger, B. L. (1989) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)84282-5 · Cited by 175
Self-citationFraction collector for capillary zone electrophoresis
Rose, D. J., & Jorgenson, J. W. (1988) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)90229-2 · Cited by 90
Cited by
Initial sequencing and analysis of the human genome
International Human Genome Sequencing Consortium, Whitehead Institute for Biomedical Research, C. F. G. R., Lander, E. S., Linton, L. M., Birren, B., Nusbaum, C., Zody, M. C., Baldwin, J., Devon, K., Dewar, K., et al. (2001) · Nature · doi:10.1038/35057062 · Cited by 24,216
Seebach, D. (1990) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199013201 · Cited by 577
Heiger, D. N., Cohen, A. S., & Karger, B. L. (1990) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)90202-x · Cited by 397
Self-citationAnalysis of therapeutic nucleic acids by capillary electrophoresis
Wei, B., Goyon, A., & Zhang, K. (2022) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2022.114928 · Cited by 50
Metadata
- Authors
- Guttman, A., Cohen, A. S., Heiger, D. N., & Karger, B. L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1990-01-15
- Volume
- 62
- Issue
- 2
- Pages
- 137-141
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1993288755
- Cited by
- 261
- References
- 10
- FWCI
- 42.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.