CoChat

Precise isotopic analysis of uranium in picomole and subpicomole quantities

Chen, J. H., Wasserburg, G. J. · 1981 · Analytical Chemistry
Cited by 156

The DOI matches its Crossref record.

Abstract

A procedure for the separation of U and measurement of U isotopes in meteoritic, lunar, and terrestrial samples Is described. Accurate ²³⁸U/²³⁵U ratios and U concentration measurements can be done on a routine basis at the level of ~10⁻¹³ mol of U by isotope dilution using a double tracer composed of ²³³U and ²³⁶U. Precise determination of the number of U atoms in a sample can be done at the level of 10⁸-10⁹ atoms. The technique Involves careful control of the chemical procedures to eliminate laboratory contamination and precise calibration of the mass spectrometer in order to obtain high reproducibility. The ²³⁸U/²³⁵U ratios were measured on a wide variety of samples which include (1) bulk meterorites, (2) lunar samples, (3) coarse-grained Ca-Al-Tl-rich inclusions and (4) fine-grained AI-Mg-Na-rich Inclusions from the Allende meteorite, and (5) phosphates from three meteorites. The results show the same Isotopic values within limits of errors as that measured on normal terrestrial U to within 4‰. All of the analyzed meteorite samples are very ancient and several of them show large fractionations of U relative to Th and Nd. These data Imply that ²⁴⁷Cm was not abundant in the early solar system (²⁴⁷Cm/²³⁵U « 4 X 10⁻³) and that the last major "r” process terminated at ~10⁸ years prior to the formation of the solar system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac00236a027

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Chen, J. H., & Wasserburg, G. J.
Venue
Analytical Chemistry
Published
1981-11-01
Volume
53
Issue
13
Pages
2060-2067
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2094168809
Cited by
156
References
0
FWCI
3.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.