The DOI matches its Crossref record.
Flow Cytometry of Escherichia coli on Microfluidic Devices
Abstract
Flow cytometry of the bacterium Escherichia coli was demonstrated on a microfabricated fluidic device (microchip). The channels were coated with poly(dimethylacrylamide) to prevent cell adhesion, and the cells were transported electrophoretically by applying potentials to the fluid reservoirs. The cells were electrophoretically focused at the channel cross and detected by coincident light scattering and fluorescence. The E. coli were labeled with a membrane-permeable nucleic acid stain (Syto15), a membrane-impermeable nucleic acid stain (propidium iodide), or a fluorescein-labeled antibody and counted at rates from 30 to 85 Hz. The observed labeling efficiencies for the dyes and antibody were greater than 94%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Micro Total Analysis Systems. 2. Analytical Standard Operations and Applications
Auroux, P.-A., Iossifidis, D., Reyes, D. R., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac020239t · Cited by 1,532
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Abgrall, P., & Gué, A.-M. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/5/r01 · Cited by 561
Lab-on-a-chip for drug development
Weigl, B. H., Bardell, R. L., & Cabrera, C. R. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00223-5 · Cited by 481
Microfluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
Microfluidics for flow cytometric analysis of cells and particles
Huh, D., Gu, W., Kamotani, Y., Grotberg, J. B., & Takayama, S. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/3/r02 · Cited by 396
Microfluidic Devices for the High-Throughput Chemical Analysis of Cells
McClain, M. A., Culbertson, C. T., Jacobson, S. C., Allbritton, N. L., Sims, C. E., & Ramsey, J. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346510 · Cited by 383
Self-citationRecent advances in microfluidic technologies for cell-to-cell interaction studies
Rothbauer, M., Zirath, H., & Ertl, P. (2018) · Lab on a Chip · doi:10.1039/c7lc00815e · Cited by 277
Label-Free Detection of Single Living Bacteria via Electrochemical Collision Event
Lee, J. Y., Kim, B.-K., Kang, M., & Park, J. H. (2016) · Scientific Reports · doi:10.1038/srep30022 · Cited by 89
Metadata
- Authors
- McClain, M. A., Culbertson, C. T., Jacobson, S. C., & Ramsey, J. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-10-03
- Volume
- 73
- Issue
- 21
- Pages
- 5334-5338
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2080016122
- Cited by
- 224
- References
- 0
- FWCI
- 14.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.