Label-Free Detection of Single Living Bacteria via Electrochemical Collision Event

Open access
Lee, Ji Young, Kim, Byung-Kwon, Kang, Mijeong, Park, Jun Hui·2016·Scientific Reports

Abstract

We detected single living bacterial cells on ultramicroelectrode (UME) using a single-particle collision method and optical microscopic methods. The number of collision events involving the bacterial cells indicated in current-time (i-t) curves corresponds to the number of bacterial cells (i.e., Escherichia coli) on the UME surface, as observed visually. Simulations were performed to determine the theoretical current response (75 pA) and frequency (0.47 pM−1 s−1) of single Escherichia coli collisions. The experimental current response (83 pA) and frequency (0.26 pM−1 s−1) were on the same order of magnitude as the theoretical values. This single-particle collision approach facilitates detecting living bacteria and determining their concentration in solution and could be widely applied to studying other bacteria and biomolecules.

AI snapshot

Written from the paper’s full text.

TL;DR

The paper demonstrates label-free electrochemical detection of single living *Escherichia coli* by observing staircase current decreases when bacteria collide with and block a 10 μm carbon ultramicroelectrode. Experimental current steps and collision frequencies were on the same order of magnitude as Comsol simulations, and collision counts matched fluorescence microscopy counts of EGFP-expressing *E. coli*.

Key findings

  • Single *E. coli* collisions produced staircase current responses; the experimental current step was 83 pA, close to the simulated 75 pA.
  • The experimental collision frequency was 0.26 pM⁻¹ s⁻¹, compared with a simulated theoretical frequency of 0.47 pM⁻¹ s⁻¹.
  • In one measurement, 7 electrochemical collision responses over 500 s corresponded to 7 fluorescent *E. coli* on the UME surface.
  • Collision frequency versus *E. coli* concentration was linear from 10 to 100 fM and saturated at 212 fM because the fully covered UME reduced the electroactive area and migrational flux.

Methods

  • A 10 μm carbon-fiber ultramicroelectrode (C-UME) was used in a three-electrode cell with Ag/AgCl reference and Pt counter electrode; ferrocyanide oxidation generated a positive field that attracted negatively charged *E. coli*, and collision/attachment blocked redox flux.
  • *E. coli* DH5α was cultivated in LB medium with kanamycin at 37 °C, and EGFP was expressed with 0.1 mM IPTG for fluorescence confirmation; collision events were measured by current-time curves and compared with fluorescence microscopy and SEM.
  • 3-D and 2-D Comsol Multiphysics simulations estimated current-step height and collision frequency; control experiments used *E. coli*-free LB medium and ruthenium(III) hexamine to test the role of migrational movement.

Limitations

  • The paper states that the simulation considered only diffusional and attractive migrational movement of *E. coli*, and it notes that complex *E. coli* movement hardly affected overall collision frequency.
  • The paper states that high redox concentrations may damage living *E. coli*, so relatively low Fe(CN)₆⁴⁻ concentrations were required; 20 mM was chosen to balance signal and cell stability.
  • Text-evident limitations: detection was demonstrated only for *E. coli*; the concentration–frequency relationship was linear only from 10 to 100 fM and saturated at 212 fM; and current-step height depended on *E. coli* alignment and landing position on the UME.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1038/srep30022

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Claims the paper makes

2 of 5 cited sources checked · 0 supported · 1 flagged · accuracy not yet measured

  • Premisecitation

    It is difficult to monitor or capture living bacteria, which are small and move by swimming, swarming, gliding, and twitching in solution.

    “However, it is difficult to monitor or capture living bacteria, which are small and move by swimming, swarming, gliding, and twitching in solution14.”
    Quote in the paperSubstantial claim1 of 1 sources checked
    • cites [14] Kearns, D. B. A field guide to bacterial swarming motility. Nat. Rev. Microbiol. 8, 634–644 (2010). source

      The paper’s section on studying swarming motility in the laboratory says swarming occurs over a solid surface and distinguishes it from swimming in water. That contradicts the claim that all four forms of movement occur in solution. The passages found also do not say that living bacteria are difficult to monitor or capture because they are small. (LLM, conf=0.86)

      Checked by a reasoning model — may be wrong.

      Experimental — accuracy not yet measured
  • Interpretationreasoning

    The complex movement of E. coli hardly affects the overall collision frequency.

    “This result implies that the complex movement of E. coli hardly affects the overall collision frequency.25”
    Quote in the paperSubstantial claim1 of 1 sources checked
    • cites [25] Walker, S. L., Hill, J. E., Redman, J. A. & Elimelech, M. Influence of growth phase on adhesion kinetics of Escherichia coli D21g. Appl. Environ. Microbiol. 71, 3093–3099 (2005). source

      The Results and Discussion report virtually identical bacterial transfer rates for two growth phases under favorable conditions, but attribute this finding to the small difference in cell size. The copy does not address whether E. coli’s complex movement affects overall collision frequency (searched: movement, motility, swimming, collision frequency). (LLM, conf=0.72)

      Experimental — accuracy not yet measured
    • The authors state this as an assumption: An E. coli was assumed to have a cylindrical shape with a radius of 0.4 μm and a length of 2 μm.
  • Findingown data

    The experimental current response (83 pA) and frequency (0.26 pM−1 s−1) were on the same order of magnitude as the theoretical values.

    “The experimental current response (83 pA) and frequency (0.26 pM−1 s−1) were on the same order of magnitude as the theoretical values.”
    • Also stated in: § Simulation for analysing current step decrease and collision frequency · plain
      “The experimental (0.26 pM−1 s−1) and expected (0.47 pM−1 s−1) frequencies are on the same order of magnitude.”
    Quote in the paperSubstantial claim
  • Findingown data

    The number of collision events involving bacterial cells in current-time curves corresponds to the number of bacterial cells (E. coli) on the UME surface, as observed visually.

    “The number of collision events involving the bacterial cells indicated in current-time (i-t) curves corresponds to the number of bacterial cells (i.e., Escherichia coli) on the UME surface, as observed visually.”
    • Also stated in: § Detection of multiple E. coli collisions on C-UME · plain
      “The number of adsorbed E. coli was in good agreement with the number of electrochemical collision responses.”
    • Also stated in: § Conclusions · plain
      “The number of collision responses observed in i-t curves correlates with the number of E. coli observed via fluorescence microscopy and predicted by theoretical calculations.”
    Quote in the paperSubstantial claim
  • Findingown data

    Simulations determined the theoretical current response of single E. coli collisions to be 75 pA.

    “Simulations were performed to determine the theoretical current response (75 pA) and frequency (0.47 pM−1 s−1) of single Escherichia coli collisions.”
    • Also stated in: § Simulation for analysing current step decrease and collision frequency · hedged
      “The height of the experimentally observed staircase current (83 pA) shown in Fig. 3A is in good agreement with the estimated signal height (75 pA) based on the simulation results shown in Fig. 4C (simulation details are provided in the Supplementary Dataset).”
    Quote in the paperSubstantial claim
    • The authors state this as an assumption: An E. coli was assumed to have a cylindrical shape with a radius of 0.4 μm and a length of 2 μm.
  • May combine two claims. 9
  • Classified as probably not a substantial claim. 4
  • May combine two claims.

    Findingreasoning

    When an E. coli collides with and attaches to the UME surface, the steady-state current decreases immediately because the flux of the redox species is blocked by the E. coli, producing a staircase current response.

    “When an E. coli collides with and then attaches to the UME surface, the level of the steady-state current decreases immediately because the flux of the redox species is blocked by the E. coli. Therefore, a staircase current response is observed (Fig. 1).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    One collision signal was detected for 90 s, and after collecting the electrochemical collision signal, fluorescent microscopy showed green E. coli on the UME surface.

    “As shown in Fig. 3A, one collision signal was detected for 90 s. After collecting the electrochemical collision signal, the electrode surface was observed by fluorescent microscopy (Fig. 3B). The green-colored E. coli on the UME surface were clearly observabled.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    Seven collision responses were observed over 500 s, and seven fluorescent E. coli were present on the UME surface.

    “In this case, 7 collision responses were observed over 500 s (Fig. 3C). As shown in Fig. 3D, 7 fluorescent E. coli were present on the UME surface (black circles).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    The microscopic images confirmed that the adsorbed particle on the electrode surface is an E. coli and that the cell cannot be easily detached.

    “These microscopic images confirmed that the adsorbed particle on the electrode surface is an E. coli and that the cell cannot be easily detached.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    In the presence of 20 mM Fe(CN)64─, E. coli collision resulted in a response of tens of pA, which exceeds the instrumental lower limit (a few pA) by one order of magnitude.

    “In the presence of 20 mM Fe(CN)64─, E. coli collision resulted in a response of tens of pA, which exceeds the instrumental lower limit (a few pA) by one order of magnitude.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    Staircase current responses were observed upon single E. coli collision for all studied concentrations of redox species, and the current step height was proportional to the redox species concentration.

    “As shown in Fig. 2, staircase current responses were observed upon single E. coli collision for all studied concentrations, and the current step height was proportional to the redox species concentration (Supplementary Fig. S1).”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S4 (based).

    Interpretationnone given

    When ferrocyanide is oxidized at the electrode surface, a positive electric field is developed by the steady-state current flow.

    “When the ferrocyanide (Fe(CN)64─) is oxidized at the electrode surface, a positive electric field is developed by the steady-state current flow.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S2 (checkable), S3 (load-bearing).

    Interpretationreasoning

    The approach could be widely applied to studying other bacteria and biomolecules.

    “This single-particle collision approach facilitates detecting living bacteria and determining their concentration in solution and could be widely applied to studying other bacteria and biomolecules.”
    • Also stated in: § Conclusions · plain
      “This approach can also be applied to study other biomolecules.”
    Quote in the paperNot a substantial claim
    • Rests on an assumption: Label-free detection of single living microbes has not been reported to date.
  • May combine two claims.

    Interpretationown data

    The single-particle collision approach facilitates detecting living bacteria and determining their concentration in solution.

    “This single-particle collision approach facilitates detecting living bacteria and determining their concentration in solution and could be widely applied to studying other bacteria and biomolecules.”
    • Also stated in: § Conclusions · plain
      “Therefore, this methodology can be applied to measure the concentrations of specific-sized microbes in solution.”
    Quote in the paperSubstantial claim
    • Rests on an assumption: Label-free detection of single living microbes has not been reported to date.
  • May combine two claims.

    Interpretationown data

    The concentration of 20 mM Fe(CN)64─ is low enough to prevent osmotic cell death but high enough to result in observable signal intensity.

    “This concentration is low enough to prevent osmotic cell death but high enough to result in observable signal intensity.”
    Quote in the paperSubstantial claim
    • Rests on an assumption: High concentrations of redox species may cause unexpected damage to the living E. coli.
  • Classified as probably not a substantial claim.

    Premisecitation

    The particle size-to-UME diameter ratio must be optimized to produce an obvious staircase current.

    “Next, the particle size-to-UME diameter ratio must be optimized to produce an obvious staircase current322.”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites [3] Boika, A., Thorgaard, S. N. & Bard, A. J. Monitoring the electrophoretic migration and adsorption of single insulating nanoparticles at ultramicroelectrodes. J. Phys. Chem. B 117, 4371–4380 (2013). source
    • cites [22] Fosdick, S. E., Anderson, M. J., Nettleton, E. G. & Crooks, R. M. Correlated Electrochemical and Optical Tracking of Discrete Collision Events. J. Am. Chem. Soc. 135, 5994–5997 (2015). source
  • Probably not a substantial claim: may not pass S4 (based). May combine two claims.

    Interpretationnone given

    This blocking method is faster and simpler than the conventional methods used to detect living bacteria in solution.

    “This blocking method is faster and simpler than the conventional methods used to detect living bacteria in solution.”
    Quote in the paperNot a substantial claim
12 of 12
  • The paper relies on this without support.

    Label-free detection of single living microbes has not been reported to date.

    “Interesting features of various single biomolecules have been observed1213, but label-free detection of single living microbes has not been reported to date.”
  • The authors state this as an assumption.

    An E. coli was assumed to have a cylindrical shape with a radius of 0.4 μm and a length of 2 μm.

    “in our simulation, an E. coli was assumed to have a cylindrical shape with a radius of 0.4 μm and a length of 2 μm”
  • The paper relies on this without support.

    High concentrations of redox species may cause unexpected damage to the living E. coli.

    “However, such high concentrations of redox species may cause unexpected damage to the living E. coli.”
3 of 3

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Blocking electrochemical impacts were extended to single bacteria detection for the first time in 2016 by Lee et al. with E. coli.

    “Blocking electrochemical impacts have been extended to single bacteria detection for the first time in 2016 by Lee et al. with E. coli [29].”
  • The blocking electrochemical impacts method has been widely extended to the detection of various micro- and nano-objects, with specific interest in single collisions of bio-entities such as proteins, viruses, and bacteria.

    “In the following years, this method has been widely extended to the detection of various micro-and nano-objects, with a specific interest in single collisions of bio-entities such as proteins, viruses, and bacteria [19,25,29,35].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lee, J. Y., Kim, B.-K., Kang, M., & Park, J. H.
Affiliations
  • Korea Advanced Institute of Science and Technology (KR)
  • Sookmyung Women's University (KR)
  • University of Maryland, College Park (US)
  • Jeonbuk National University (KR)
Venue
Scientific Reports
Published
2016-07-20
Volume
6
Issue
1
Pages
30022-30022
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2484399586
Cited by
89
References
25
Citations by year
2026: 5 · 2025: 1 · 2024: 13 · 2023: 9 · 2022: 6 · 2021: 12 · 2020: 15 · 2019: 9 · 2018: 13 · 2017: 4 · 2016: 2
FWCI
5.01
Type
journal article
Language
en
Open access
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • PubMed Central (submittedVersion, cc-by)
Funders
  • National Research Foundation
  • Chonbuk National University
  • Sookmyung Women's University
  • Ministry of Science, ICT and Future Planning (2015R1C1A1A01055250, NRF-2015R1C1A1A01055250, NRF-2013R1A1A1059719)
  • National Research Foundation of Korea (NRF-2015R1C1A1A01055250)
Topics
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
Keywords
label-free detection, ultramicroelectrodes, Escherichia coli, current-time curves, collision frequency, electrochemical biosensor
MeSH terms
Escherichia coli, Microscopy, Electrochemical Techniques, Bacterial Load

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-11.

Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-11.

Cited sources are checked by gpt-6-sol.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review