Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,033

The DOI matches its Crossref record.

Lead Phthalocyanine as a Selective Carrier for Preparation of a Cysteine-Selective Electrode

Shahrokhian, Saeed·2001·Analytical Chemistry

Abstract

A novel cysteine-selective electrode based on lead phthalocyanine (PbPc) as ionophore is described. The electrode was prepared by incorporating PbPc into a plasticized poly(vinyl chloride) (PVC) membrane, which was directly coated on the surface of a graphite electrode. This electrode shows high selectivity for the response to cysteine, as compared with many common inorganic anions, salicylate, and other kinds of amino acids. The influence of membrane composition, pH, and the effect of lipophilic cationic and anionic additives on the response characteristics of the electrode were investigated. The resulting sensor demonstrates nernstian response over a wide linear range of cysteine concentration (1 x 10(-6) to 5 x 10(-2) M). The electrode has a fast response time, micromolar detection limit (approximately 1 x 10(-6) M), and good long-term stability (more than 1 month). The prepared electrode was used for determination of cysteine in a synthetic human serum sample, and very good recovery results were obtained over a wide concentration range of cysteine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac010541m

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 1,033

Metadata

Authors
Shahrokhian, S.
Venue
Analytical Chemistry
Published
2001-11-08
Volume
73
Issue
24
Pages
5972-5978
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2024422280
Cited by
1,033
References
0
FWCI
4.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Lead Phthalocyanine as a Selective Carrier for Preparation of a Cysteine-Selective Electrode. https://app.cochat.ai/papers/10.1021/ac010541m
The paper
Shahrokhian, S. (2001). Lead Phthalocyanine as a Selective Carrier for Preparation of a Cysteine-Selective Electrode. Analytical Chemistry. https://doi.org/10.1021/ac010541m

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.