The DOI matches its Crossref record.
Lead Phthalocyanine as a Selective Carrier for Preparation of a Cysteine-Selective Electrode
Abstract
A novel cysteine-selective electrode based on lead phthalocyanine (PbPc) as ionophore is described. The electrode was prepared by incorporating PbPc into a plasticized poly(vinyl chloride) (PVC) membrane, which was directly coated on the surface of a graphite electrode. This electrode shows high selectivity for the response to cysteine, as compared with many common inorganic anions, salicylate, and other kinds of amino acids. The influence of membrane composition, pH, and the effect of lipophilic cationic and anionic additives on the response characteristics of the electrode were investigated. The resulting sensor demonstrates nernstian response over a wide linear range of cysteine concentration (1 x 10(-6) to 5 x 10(-2) M). The electrode has a fast response time, micromolar detection limit (approximately 1 x 10(-6) M), and good long-term stability (more than 1 month). The prepared electrode was used for determination of cysteine in a synthetic human serum sample, and very good recovery results were obtained over a wide concentration range of cysteine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescent and colorimetric probes for detection of thiols
Chen, X., Zhou, Y., Peng, X., & Yoon, J. (2010) · Chemical Society Reviews · doi:10.1039/b925092a · Cited by 1,580
Design strategies of fluorescent probes for selective detection among biothiols
Niu, L.-Y., Chen, Y.-Z., Zheng, H.-R., Wu, L.-Z., Tung, C.-H., & Yang, Q.-Z. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00152h · Cited by 870
Yang, X., Guo, Y., & Strongin, R. M. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201103759 · Cited by 658
Detection of Homocysteine and Cysteine
Wang, W., Rusin, O., Xu, X., Kim, K. K., Escobedo, J. O., Fakayode, S. O., Fletcher, K. A., Lowry, M., Schowalter, C. M., Lawrence, C. M., et al. (2005) · Journal of the American Chemical Society · doi:10.1021/ja054962n · Cited by 593
Thiol-addition reactions and their applications in thiol recognition
Yin, C., Huo, F., Zhang, J., Martínez-Máñez, R., Yang, Y., Lv, H., & Li, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60055f · Cited by 554
Reaction-based BODIPY probes for selective bio-imaging
Kolemen, S., & Akkaya, E. U. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.06.021 · Cited by 357
Li, H., Fan, J., Wang, J., Tian, M., Du, J., Sun, S., Sun, P., & Peng, X. (2009) · Chemical Communications · doi:10.1039/b907511a · Cited by 339
Han, B., Yuan, J., & Wang, E. (2009) · Analytical Chemistry · doi:10.1021/ac900769h · Cited by 316
A thiol-specific fluorescent probe and its application for bioimaging
Chen, X., Ko, S.-K., Kim, M. J., Shin, I., & Yoon, J. (2010) · Chemical Communications · doi:10.1039/b925453f · Cited by 289
Two-photon luminescent metal complexes for bioimaging and cancer phototherapy
Chen, Y., Guan, R., Zhang, C., Huang, J., Ji, L., & Chao, H. (2016) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2015.09.010 · Cited by 259
Metadata
- Authors
- Shahrokhian, S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-11-08
- Volume
- 73
- Issue
- 24
- Pages
- 5972-5978
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2024422280
- Cited by
- 1,033
- References
- 0
- FWCI
- 4.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.