Electrochemically Induced pH Changes Resulting in Protein Unfolding in the Ion Source of an Electrospray Mass Spectrometer
The DOI matches its Crossref record.
Abstract
The operation of an electrospray ion source in the positive ion mode involves charge-balancing oxidation reactions at the liquid/metal interface of the sprayer capillary. One of these reactions is the electrolytic oxidation of water. The protons generated in this process acidify the analyte solution within the electrospray capillary. This work explores the effects of this acidification on the electrospray ionization (ESI) mass spectrum of the protein cytochrome c (cyt c). In aqueous solution containing 40% propanol, cyt c unfolds around pH 5.6. Mass spectra recorded under these conditions, using a simple ESI series circuit, display a bimodal charge-state distribution that reflects an equilibrium mixture of folded and unfolded protein in solution. These spectra are not strongly affected by electrochemical acidification. An "external loop" is added to the ESI circuit when the metal needle of the sample injection syringe is connected to ground. The resulting circuit represents two coupled electrolytic cells that share the ESI capillary as a common anode. Under these conditions, the rate of charge-balancing oxidation reactions is dramatically increased because the ion source has to supply electrons for both, the external circuit and the ESI circuit. The analytical implications of this effect are briefly discussed. Mass spectra of cyt c recorded with the syringe needle grounded are shifted to higher charge states, indicating that electrochemical acidification has caused the protein to unfold in the ion source. The acidification can be suppressed by increasing the flow rate and lowering the electrolyte concentration of the solution and by using an electrolyte that acts as redox buffer. The observed acidification is similar for sprayer capillaries made of platinum and stainless steel. Removal of the protective oxide layer on the stainless steel surface results in effective redox buffering for a few minutes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Organic Reactions in Microdroplets: Reaction Acceleration Revealed by Mass Spectrometry
Yan, X., Bain, R. M., & Cooks, R. G. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201602270 · Cited by 583
Konermann, L. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1739-3 · Cited by 243
Self-citationSun, J., Kitova, E. N., Wang, W., & Klassen, J. S. (2006) · Analytical Chemistry · doi:10.1021/ac0522005 · Cited by 160
Hedges, J. B., Vahidi, S., Yue, X., & Konermann, L. (2013) · Analytical Chemistry · doi:10.1021/ac401020s · Cited by 109
Self-citation
Metadata
- Authors
- Konermann, L., Silva, E. A., & Sogbein, O. F.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-09-11
- Volume
- 73
- Issue
- 20
- Pages
- 4836-4844
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2089717057
- Cited by
- 96
- References
- 0
- FWCI
- 3.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemically Induced pH Changes Resulting in Protein Unfolding in the Ion Source of an Electrospray Mass Spectrometer. https://app.cochat.ai/papers/10.1021/ac010545r
- The paper
- Konermann, L., Silva, E. A., & Sogbein, O. F. (2001). Electrochemically Induced pH Changes Resulting in Protein Unfolding in the Ion Source of an Electrospray Mass Spectrometer. Analytical Chemistry. https://doi.org/10.1021/ac010545r
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.