The DOI matches its Crossref record.
Palladium Mesowire Arrays for Fast Hydrogen Sensors and Hydrogen-Actuated Switches
Abstract
Arrays of mesoscopic palladium wires prepared by electrodeposition form the basis for hydrogen sensors and hydrogen-actuated switches that exhibit a response time ranging from 20 ms to 5 s, depending on the hydrogen concentration. These devices were constructed by electrodepositing palladium mesowires on a highly oriented pyrolytic graphite surface and then transferring these mesowires to a cyanoacrylate film supported on a glass slide. The application of silver contacts to the ends of 10-100 mesowires, arrayed electrically in parallel, produced sensors and switches that exhibited a high conductivity state in the presence of hydrogen and a low conductivity state in the absence of hydrogen. After an initial exposure to hydrogen, 15-50 nanoscopic gaps are formed in each mesowire. These nanoscopic gaps or "break junctions" close in the presence of hydrogen gas and reopen in its absence as hydrogen is reversibly occluded by the palladium grains in each wire, and the palladium lattice expands and contracts by several percent. The change in resistance for sensors and switches was related to the hydrogen concentration over a range from 1 to 10%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
One‐Dimensional Nanostructures: Synthesis, Characterization, and Applications
Xia, Y., Yang, P., Sun, Y., Wu, Y., Mayers, B., Gates, B., Yin, Y., Kim, F., & Yan, H. (2003) · Advanced Materials · doi:10.1002/adma.200390087 · Cited by 8,559
New Approaches to Nanofabrication: Molding, Printing, and Other Techniques
Gates, B. D., Xu, Q., Stewart, M., Ryan, D., Willson, C. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr030076o · Cited by 2,020
Nanoantenna-enhanced gas sensing in a single tailored nanofocus
Liu, N., Tang, M. L., Hentschel, M., Giessen, H., & Alivisatos, A. P. (2011) · Nature Materials · doi:10.1038/nmat3029 · Cited by 950
Chemical sensors based on nanostructured materials
Huang, X.-J., & Choi, Y.-K. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.06.022 · Cited by 662
Selectivity in Chemiresistive Gas Sensors: Strategies and Challenges
Bulemo, P. M., Kim, D.-H., Shin, H., Cho, H.-J., Koo, W.-T., Choi, S.-J., Park, C., Ahn, J., Güntner, A. T., Penner, R. M., et al. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00592 · Cited by 418
Self-citationChen, X., Wong, C. K. Y., Yuan, C. A., & Zhang, G. (2013) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2012.10.134 · Cited by 395
Darmadi, I., Nugroho, F. A. A., & Langhammer, C. (2020) · ACS Sensors · doi:10.1021/acssensors.0c02019 · Cited by 382
Sun, Y., & Wang, H. H. (2007) · Advanced Materials · doi:10.1002/adma.200602975 · Cited by 371
Highly Ordered Anodic Porous Alumina Formation by Self‐Organized Anodizing
Sulka, G. D. (2008) · Nanostructured Materials in Electrochemistry · doi:10.1002/9783527621507.ch1 · Cited by 292
Dunn-Rankin, D., Leal, E. M., & Walther, D. C. (2005) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2005.04.001 · Cited by 259
Metadata
- Authors
- Walter, E. C., Favier, F., & Penner, R. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-03-07
- Volume
- 74
- Issue
- 7
- Pages
- 1546-1553
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1977603461
- Cited by
- 238
- References
- 0
- FWCI
- 11.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.