The DOI matches its Crossref record.
Detection of Hydrogen Peroxide at Mesoporous Platinum Microelectrodes
Abstract
Mesoporous (H(I)-ePt) platinum microelectrodes electrodeposited from the hexagonal (H(I)) lyotropic liquid crystalline phase are shown to be excellent amperometric sensors for the detection of hydrogen peroxide over a wide range of concentrations. Good reproducibility, high precision, and accuracy of measurements are demonstrated. Mesoporous microelectrodes retain the high rates of mass transport typical of conventional microelectrodes, and their high real surface area greatly enhances their catalytic activity. This unique combination of properties overcomes the limitations of previous amperometric hydrogen peroxide sensors and yields outstanding qualitative and quantitative results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guo, S., Wen, D., Zhai, Y., Dong, S., & Wang, E. (2010) · ACS Nano · doi:10.1021/nn100852h · Cited by 752
Zhu, C., Du, D., Eychmüller, A., & Lin, Y. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00255 · Cited by 672
Mesoporous materials and electrochemistry
Walcarius, A. (2013) · Chemical Society Reviews · doi:10.1039/c2cs35322a · Cited by 623
Chen, S., & Kucernak, A. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp036831j · Cited by 216
Metadata
- Authors
- Evans, S. A. G., Elliott, J. M., Andrews, L. M., Bartlett, P. N., Doyle, P. J., & Denuault, G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-02-14
- Volume
- 74
- Issue
- 6
- Pages
- 1322-1326
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1977945830
- Cited by
- 364
- References
- 0
- FWCI
- 10.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Hydrogen Peroxide at Mesoporous Platinum Microelectrodes. https://app.cochat.ai/papers/10.1021/ac011052p
- The paper
- Evans, S. A. G., Elliott, J. M., Andrews, L. M., Bartlett, P. N., Doyle, P. J., & Denuault, G. (2002). Detection of Hydrogen Peroxide at Mesoporous Platinum Microelectrodes. Analytical Chemistry. https://doi.org/10.1021/ac011052p
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.