The DOI matches its Crossref record.
Identification of Staphylococcus a ureus and Determination of Its Methicillin Resistance by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry
Abstract
To evaluate the performance of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) in identifying Staphylococcus aureus and in determining its methicillin resistance, we analyzed 76 S. aureus clinical isolates using a linear MALDI-TOF MS. Spectral profile data obtained were compared with the database provided with the instrument, and 74% of the isolates were identified as S. aureus, as confirmed by a nuc-based PCR test. The determination of the methicillin resistance in S. aureus is based on the fact that the spectral profiles of methicillin-susceptible S. aureus (MSSA) and methicillin-resistant S. aureus (MRSA) differ greatly from each other. Replicate spectral profiles obtained from each isolate were combined to be a representative spectrum of it, and representative spectral profiles from all the isolates constitute a user's self-established database. All the spectral profiles in the database were classified into two groups based on clustering analysis, and one is for MSSA and another MRSA. There was a little discrepancy between the results from MALDI-TOF MS and from PCR. Seven isolates that are negative for the mecA gene by PCR were identified as MRSA by MALDI-TOF MS. The discrepancy may be partially explained by the heterogeneous nature of methicillin resistance in S. aureus. Our results suggested that comparison of MALDI-TOF MS spectral profiles of microorganism could serve as a simple and rapid method for bacterial identification and antibiotic susceptibility analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Seng, P., Drancourt, M., Gouriet, F., La Scola, B., Fournier, P., Rolain, J. M., & Raoult, D. (2009) · Clinical Infectious Diseases · doi:10.1086/600885 · Cited by 1,983
Clark, A. E., Kaleta, E. J., Arora, A., & Wolk, D. M. (2013) · Clinical Microbiology Reviews · doi:10.1128/cmr.00072-12 · Cited by 941
Guidelines for the validation and application of typing methods for use in bacterial epidemiology
van Belkum, A., Tassios, P. T., Dijkshoorn, L., Haeggman, S., Cookson, B., Fry, N. K., Fussing, V., Green, J., Feil, E., Gerner-Smidt, P., et al. (2007) · Clinical Microbiology and Infection · doi:10.1111/j.1469-0691.2007.01786.x · Cited by 863
Wieser, A., Schneider, L., Jung, J., & Schubert, S. (2012) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-011-3783-4 · Cited by 453
Seng, P., Abat, C., Rolain, J. M., Colson, P., Lagier, J.-C., Gouriet, F., Fournier, P. E., Drancourt, M., La Scola, B., & Raoult, D. (2013) · Journal of Clinical Microbiology · doi:10.1128/jcm.00492-13 · Cited by 438
Metadata
- Authors
- Du, Z., Yang, R., Guo, Z., Song, Y., & Wang, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-09-21
- Volume
- 74
- Issue
- 21
- Pages
- 5487-5491
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2030530116
- Cited by
- 190
- References
- 0
- FWCI
- 1.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Identification of Staphylococcus a ureus and Determination of Its Methicillin Resistance by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac020109k
- The paper
- Du, Z., Yang, R., Guo, Z., Song, Y., & Wang, J. (2002). Identification of Staphylococcus a ureus and Determination of Its Methicillin Resistance by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac020109k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.