The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Ongoing Revolution in Bacteriology: Routine Identification of Bacteria by Matrix‐Assisted Laser Desorption Ionization Time‐of‐Flight Mass Spectrometry
Abstract
BACKGROUND: Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry accurately identifies both selected bacteria and bacteria in select clinical situations. It has not been evaluated for routine use in the clinic. METHODS: We prospectively analyzed routine MALDI-TOF mass spectrometry identification in parallel with conventional phenotypic identification of bacteria regardless of phylum or source of isolation. Discrepancies were resolved by 16S ribosomal RNA and rpoB gene sequence-based molecular identification. Colonies (4 spots per isolate directly deposited on the MALDI-TOF plate) were analyzed using an Autoflex II Bruker Daltonik mass spectrometer. Peptidic spectra were compared with the Bruker BioTyper database, version 2.0, and the identification score was noted. Delays and costs of identification were measured. RESULTS: Of 1660 bacterial isolates analyzed, 95.4% were correctly identified by MALDI-TOF mass spectrometry; 84.1% were identified at the species level, and 11.3% were identified at the genus level. In most cases, absence of identification (2.8% of isolates) and erroneous identification (1.7% of isolates) were due to improper database entries. Accurate MALDI-TOF mass spectrometry identification was significantly correlated with having 10 reference spectra in the database (P=.01). The mean time required for MALDI-TOF mass spectrometry identification of 1 isolate was 6 minutes for an estimated 22%-32% cost of current methods of identification. CONCLUSIONS: MALDI-TOF mass spectrometry is a cost-effective, accurate method for routine identification of bacterial isolates in <1 h using a database comprising > or =10 reference spectra per bacterial species and a 1.9 identification score (Brucker system). It may replace Gram staining and biochemical identification in the near future.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“MALDI–time-of-flight (TOF)–MS, once considered revolutionary, is now established as a routine tool in clinical microbiology133.”
From A high-stringency blueprint of the human proteome (2020) · cites this paper as [133]
Citations
Cites
Manual of Clinical Microbiology.
(1980) · Annals of Internal Medicine · doi:10.7326/0003-4819-93-6-939_2 · Cited by 14,411
Taxonomic parameters revisited : tarnished gold standards
Stackebrandt, E. S. (2006) · Medical Entomology and Zoology · Cited by 1,895
Phylogenetic affiliation of the pseudomonads based on 16S rRNA sequence.
Anzai, Y., Kim, H., Park, J. Y., Wakabayashi, H., & Oyaizu, H. (2000) · International Journal of Systematic and Evolutionary Microbiology · doi:10.1099/00207713-50-4-1563 · Cited by 881
The rapid identification of intact microorganisms using mass spectrometry
Claydon, M. A., Davey, S. N., Edwards-Jones, V., & Gordon, D. B. (1996) · Nature Biotechnology · doi:10.1038/nbt1196-1584 · Cited by 609
Identification of bacteria using mass spectrometry
Anhalt, J. P., & Fenselau, C. (1975) · Analytical Chemistry · doi:10.1021/ac60352a007 · Cited by 504
KAWAMURA, Y., HOU, X.-G., SULTANA, F., MIURA, H., & EZAKI, T. (1995) · International Journal of Systematic Bacteriology · doi:10.1099/00207713-45-2-406 · Cited by 503
Mellmann, A., Cloud, J., Maier, T., Keckevoet, U., Ramminger, I., Iwen, P., Dunn, J., Hall, G., Wilson, D., LaSala, P., et al. (2008) · Journal of Clinical Microbiology · doi:10.1128/jcm.00157-08 · Cited by 435
The rpoB gene as a tool for clinical microbiologists
Adékambi, T., Drancourt, M., & Raoult, D. (2009) · Trends in Microbiology · doi:10.1016/j.tim.2008.09.008 · Cited by 355
Self-citationClassification and Identification of Bacteria by Mass Spectrometry and Computational Analysis
Sauer, S., Freiwald, A., Maier, T., Kube, M., Reinhardt, R., Kostrzewa, M., & Geider, K. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002843 · Cited by 335
Microorganism Identification by Mass Spectrometry and Protein Database Searches
Demirev, P. A., Ho, Y.-P., Ryzhov, V., & Fenselau, C. (1999) · Analytical Chemistry · doi:10.1021/ac990165u · Cited by 326
Cited by
MALDI-TOF mass spectrometry: an emerging technology for microbial identification and diagnosis
Singhal, N., Kumar, M., Kanaujia, P. K., & Virdi, J. S. (2015) · Frontiers in Microbiology · doi:10.3389/fmicb.2015.00791 · Cited by 1,605
“The MALDI Biotyper consisted of a basic MALDI-TOF platform, operating and analysis softwares, an onsite database and a simple method for extraction/preparation of sample (Seng et al., 2009).”
BackgroundMethodMicrobial culturomics: paradigm shift in the human gut microbiome study
Lagier, J.-C., Armougom, F., Million, M., Hugon, P., Pagnier, I., Robert, C., Bittar, F., Fournous, G., Gimenez, G., Maraninchi, M., et al. (2012) · Clinical Microbiology and Infection · doi:10.1111/1469-0691.12023 · Cited by 1,204
“55-fold the time to bacterial identification and reduces the costs by at least a factor of 5 [10].”
BackgroundMethodInfluentialSelf-citationApplications of MALDI-TOF mass spectrometry in clinical diagnostic microbiology
Croxatto, A., Prod'hom, G., & Greub, G. (2012) · FEMS Microbiology Reviews · doi:10.1111/j.1574-6976.2011.00298.x · Cited by 997
“Seng et al. (2009) showed that an improved database is required as 50% of the total isolates (46) showing no identification by MALDI-TOF MS were anaerobic bacteria including Fusobacterium nucleatum and non-Clostridium anaerobes that had no reference in the Bruker database.”
BackgroundMethodResultInfluentialLagier, J.-C., Khelaifia, S., Alou, M. T., Ndongo, S., Dione, N., Hugon, P., Caputo, A., Cadoret, F., Traore, S. I., Seck, E. H., et al. (2016) · Nature Microbiology · doi:10.1038/nmicrobiol.2016.203 · Cited by 951
Self-citationRetractedClark, A. E., Kaleta, E. J., Arora, A., & Wolk, D. M. (2013) · Clinical Microbiology Reviews · doi:10.1128/cmr.00072-12 · Cited by 941
Metadata
- Authors
- Seng, P., Drancourt, M., Gouriet, F., La Scola, B., Fournier, P., Rolain, J. M., & Raoult, D.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- Corresponding author
- Raoult, Didier
- ORCID
- Venue
- Clinical Infectious Diseases
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-08-15
- Volume
- 49
- Issue
- 4
- Pages
- 543-551
- ISSN
- 1058-4838 (ISSN-L)
- 1537-6591
- OpenAlex
- W2172112723
- Cited by
- 1,983
- References
- 50
- Citations by year
- 2026: 59 · 2025: 51 · 2024: 52 · 2023: 78 · 2022: 98 · 2021: 109 · 2020: 121 · 2019: 158 · 2018: 147 · 2017: 160 · 2016: 173 · 2015: 134 · 2014: 149 · 2013: 153 · 2012: 126
- FWCI
- 72.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Infectious Diseases (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Keywords
- MALDI-TOF mass spectrometry, bacterial identification, species identification, 16S rRNA gene sequencing, rpoB gene sequencing, identification accuracy, cost-effectiveness, biochemical identification
- MeSH terms
- Bacteria, Bacterial Infections, Bacterial Proteins, Bacteriological Techniques, Diagnostic Errors, Humans, Retrospective Studies, Sensitivity and Specificity, Time Factors, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ongoing Revolution in Bacteriology: Routine Identification of Bacteria by Matrix‐Assisted Laser Desorption Ionization Time‐of‐Flight Mass Spectrometry. https://app.cochat.ai/papers/10.1086/600885
- The paper
- Seng, P., Drancourt, M., Gouriet, F., La Scola, B., Fournier, P., Rolain, J. M., & Raoult, D. (2009). Ongoing Revolution in Bacteriology: Routine Identification of Bacteria by Matrix‐Assisted Laser Desorption Ionization Time‐of‐Flight Mass Spectrometry. Clinical Infectious Diseases. https://doi.org/10.1086/600885
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.