The Influence of Correlated Calibration Samples on the Prediction Performance of Multivariate Models Based on Mid-Infrared Spectra of Animal Cell Cultures
Open accessThe DOI matches its Crossref record.
Abstract
The effect of the presence of metabolism-induced concentration correlations in the calibration samples on the prediction performance of partial least-squares regression (PLSR) models and mid-infrared spectra from Chinese hamster ovary cell cultures was investigated. Samples collected from batch cultures contained highly correlated metabolite concentrations as a result of metabolic relations. Calibrations based on such samples could only be used to predict concentrations in new samples if a similar correlation structure was present and failed when the new samples were randomly spiked with the analytes. On the other hand, such models were able to predict glucose correctly even if they were based on a spectral range in which glucose does not absorb, provided that the correlations in the calibration and in the new samples were similar. If however, samples from a calibration culture were randomly spiked with the main analytes, much more robust PLSR models resulted. It was possible to predict analyte concentrations in new samples irrespective of whether the correlation structure was maintained or not. Validity of all established models for any given use could be predicted a priori by computing the space inclusion and observer conditions. Predictions from these computations agreed in all cases with the experimental test of model validity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
“These multivariate methods are prone to spurious correlations that can generate apparently functional glucose measurements in the complete absence of glucose-specific analytical information (166,167).”
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Diabetes Care · doi:10.2337/dc11-9998 · Cited by 718
“These multivariate methods are prone to spurious correlations that can generate apparently functional glucose measurements in the complete absence of glucose-specific analytical information (166,167).”
On-line infrared spectroscopy for bioprocess monitoring
Landgrebe, D., Haake, C., Höpfner, T., Beutel, S., Hitzmann, B., Scheper, T., Rhiel, M., & Reardon, K. F. (2010) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-010-2743-8 · Cited by 134
“Table 1 (continued) Microorganism/cell line Analyte Method Source S. cerevisiae Cell density NIR Ge et al. (1994) S. cerevisiae Biomass NIR Kiviharju et al. (2007) S. cerevisiae Glucose MIR Mazarevica et al. (2004) Ethanol S. cerevisiae 1-Phenyl-1,2-propandion MIR Trevisan and Poppi (2008) ®-1-Hydroxy-1-phenyl-2-propa…”
BackgroundSelf-citationOn‐line monitoring of Phaffia rhodozyma fed‐batch process with in situ dispersive raman spectroscopy
Cannizzaro, C., Rhiel, M., Marison, I., & von Stockar, U. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10698 · Cited by 70
“However, due to the nonspecific nature of NIR and very low astaxanthin concentration (on the order of milligrams per liter), it is unlikely that astaxanthin was measured directly, but rather the measurement was based on the increasing biomass concentration (Rhiel et al., 2002).”
BackgroundSelf-citationGoldrick, S., Umprecht, A., Tang, A., Zakrzewski, R., Cheeks, M., Turner, R., Charles, A., Les, K., Hulley, M., Spencer, C., et al. (2020) · Processes · doi:10.3390/pr8091179 · Cited by 48
“[69] during the analysis of the main metabolites of a CHO cell culture using a MIR probe.”
Background
Metadata
- Authors
- Rhiel, M. H., Amrhein, M. I., Marison, I. W., & von Stockar, U.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-09-18
- Volume
- 74
- Issue
- 20
- Pages
- 5227-5236
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1975126342
- Cited by
- 33
- References
- 0
- FWCI
- 1.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Influence of Correlated Calibration Samples on the Prediction Performance of Multivariate Models Based on Mid-Infrared Spectra of Animal Cell Cultures. https://app.cochat.ai/papers/10.1021/ac020165l
- The paper
- Rhiel, M. H., Amrhein, M. I., Marison, I. W., & von Stockar, U. (2002). The Influence of Correlated Calibration Samples on the Prediction Performance of Multivariate Models Based on Mid-Infrared Spectra of Animal Cell Cultures. Analytical Chemistry. https://doi.org/10.1021/ac020165l
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.