The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Enzymatic Microreactor-on-a-Chip: Protein Mapping Using Trypsin Immobilized on Porous Polymer Monoliths Molded in Channels of Microfluidic Devices
Abstract
Enzymatic microreactors have been prepared in capillaries and on microfluidic chips by immobilizing trypsin on porous polymer monoliths consisting of 2-vinyl-4,4-dimethylazlactone, ethylene dimethacrylate, and acrylamide or 2-hydroxyethyl methacrylate. The azlactone functionalities react readily with amine and thiol groups of the enzyme to form stable covalent bonds. The optimized porous properties of the monoliths lead to very low back pressures enabling the use of simple mechanical pumping to carry out both the immobilization of the enzyme from its solution and the subsequent analyses of substrate solutions. The Michealis-Menten kinetic characteristics of the reactors were probed using a low molecular weight substrate: N-alpha-benzoyl-L-arginine ethyl ester. The effects of immobilization variables such as the concentration of trypsin in solution and percentage of azlactone functionalities in the monolith, as well as the effect of reaction time on the enzymatic activity, and of process variables such as substrate flow velocity and residence time in the reactor, were studied in detail. The proteolytic activity of the enzymatic microreactor on chip was demonstrated at different flow rates with the cleavage of fluorescently labeled casein used as a substrate. The excellent performance of the monolithic microreactor was also demonstrated with the digestion of myoglobin at the fast flow rate of 0.5 microL/min, which affords a residence time of only 11.7 s. The digest was then characterized using MALDI-TOF MS, and 102 out of 153 possible peptide fragments were identified giving a sequence coverage of 67%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Merritt, A. J. (1964) · Microchemical Journal · doi:10.1016/0026-265x(64)90139-0 · Cited by 5,166
Clauser, K. R., Baker, P., & Burlingame, A. L. (1999) · Analytical Chemistry · doi:10.1021/ac9810516 · Cited by 1,093
Continuous rods of macroporous polymer as high-performance liquid chromatography separation media
Svec, F., & Frechet, J. M. J. (1992) · Analytical Chemistry · doi:10.1021/ac00031a022 · Cited by 951
Self-citationProtein identification methods in proteomics
Gevaert, K., & Vandekerckhove, J. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:6<1145::aid-elps1145>3.0.co;2-z · Cited by 338
Electroosmosis- and Pressure-Driven Chromatography in Chips Using Continuous Beds
Ericson, C., Holm, J., Ericson, T., & Hjertén, S. (2000) · Analytical Chemistry · doi:10.1021/ac990802g · Cited by 278
Integrated Microanalytical Technology Enabling Rapid and Automated Protein Identification
Ekström, S., Önnerfjord, P., Nilsson, J., Bengtsson, M., Laurell, T., & Marko‐Varga, G. (1999) · Analytical Chemistry · doi:10.1021/ac990731l · Cited by 231
Dodge, A., Fluri, K., Verpoorte, E., & de Rooij, N. F. (2001) · Analytical Chemistry · doi:10.1021/ac0015366 · Cited by 199
Jones, L. J., Upson, R. H., Haugland, R. P., Panchuk-Voloshina, N., Zhou, M., & Haugland, R. P. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2259 · Cited by 181
Drott, J., Lindström, K., Rosengren, L., et al. (1997) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/7/1/004 · Cited by 155
Product Review: Flow injection Analysis; Quietly Pushing Ahead
Smith, J. P., & Hinson-Smith, V. (2002) · Analytical Chemistry · doi:10.1021/ac022064t · Cited by 50
Chip-based nanovials for tryptic digest and capillary electrophoresis
Litborn, E., Emmer, Å., & Roeraade, J. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00486-9 · Cited by 36
Cited by
Microfluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
Microfluidic systems in proteomics
Lion, N., Rohner, T. C., Dayon, L., Arnaud, I. L., Damoc, E., Youhnovski, N., Wu, Z., Roussel, C., Josserand, J., Jensen, H., et al. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305629 · Cited by 262
Koo, H.-J., & Velev, O. D. (2017) · Biomicrofluidics · doi:10.1063/1.4978617 · Cited by 23
Metadata
- Authors
- Peterson, D. S., Rohr, T., Svec, F., & Fréchet, J. M. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-07-03
- Volume
- 74
- Issue
- 16
- Pages
- 4081-4088
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2050682768
- Cited by
- 345
- References
- 11
- FWCI
- 24.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.