The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Hydrogel-Based Microreactors as a Functional Component of Microfluidic Systems
Abstract
A simple two-step method for fabricating poly(ethylene glycol) (PEG) hydrogel-based microreactors and microsensors within microfluidic channels is described. The intrachannel micropatches contain either a dye, which can report the pH of a solution within a fluidic channel, or enzymes that are able to selectively catalyze specific reactions. Analytes present within the microfluidic channel are able to diffuse into the micropatches, encounter the enzymes, and undergo conversion to products, and then the products interact with the coencapsulated dye to signal the presence of the original substrate. The micropatches are prepared by photopolymerizing the PEG precursor within the channel of a microfluidic system consisting of a poly(dimethylsiloxane) mold and a glass plate. Exposure takes place through a slit mask oriented perpendicular to the channel, so the size of the resulting micropatch is defined by the channel dimensions and the width of the slit mask. Following polymerization, the mold is removed, leaving behind the micropatch(es) atop the glass substrate. The final microfluidic device is assembled by irreversibly binding the hydrogel-patterned glass slide to a second PDMS mold that contains a larger channel. Multiple micropatches containing the same or different enzymes can be fabricated within a single channel. The viability of this approach is demonstrated by sensing glucose using micropatches copolymerized with glucose oxidase, horseradish peroxidase, and a pH-sensitive dye.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The trk Proto-Oncogene Product: a Signal Transducing Receptor for Nerve Growth Factor
Kaplan, D. R., Hempstead, B. L., Martin-Zanca, D., Chao, M. V., & Parada, L. F. (1991) · Science · doi:10.1126/science.1850549 · Cited by 1,379
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Hydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology
Peppas, N. A., Hilt, J. Z., Khademhosseini, A., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501612 · Cited by 4,109
Hydrogels in regenerative medicine
Slaughter, B. V., Khurshid, S. S., Fisher, O. Z., Khademhosseini, A., & Peppas, N. A. (2009) · Advanced Materials · doi:10.1002/adma.200802106 · Cited by 2,703
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Magnetite-Containing Spherical Silica Nanoparticles for Biocatalysis and Bioseparations
Yang, H.-H., Zhang, S.-Q., Chen, X.-L., Zhuang, Z.-X., Xu, J.-G., & Wang, X.-R. (2004) · Analytical Chemistry · doi:10.1021/ac034920m · Cited by 510
Spatial and temporal control of the alkyne–azide cycloaddition by photoinitiated Cu(II) reduction
Adzima, B. J., Tao, Y., Kloxin, C. J., DeForest, C. A., Anseth, K. S., & Bowman, C. N. (2011) · Nature Chemistry · doi:10.1038/nchem.980 · Cited by 401
Protein immobilization techniques for microfluidic assays
Kim, D., & Herr, A. E. (2013) · Biomicrofluidics · doi:10.1063/1.4816934 · Cited by 376
Metadata
- Authors
- Zhan, W., Seong, G. H., & Crooks, R. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-08-16
- Volume
- 74
- Issue
- 18
- Pages
- 4647-4652
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2052527966
- Cited by
- 163
- References
- 1
- FWCI
- 9.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.