The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Headspace Liquid-Phase Microextraction of Chlorobenzenes in Soil with Gas Chromatography-Electron Capture Detection
Abstract
The organic solvent film formed in a microsyringe barrel was used as an extraction interface in headspace liquid-phase microextraction (HS-LPME) of chlorobenzenes. Some common organic solvents with different vapor pressures (9.33-12 918.9 Pa) were studied as extractants. The results indicated that even the solvent with the highest vapor pressure (cyclohexane) can be used to carry out the extraction successfully. In general, the reasons for successful extraction are the very small space (5 mm3) within the microsyringe barrel and the fast equilibrium between gaseous analytes and organic solvent film. Both of these factors significantly reduced the risk of solvent loss during extraction. Thus, the choice of extraction solvent for the present method was very flexible. From the viewpoint of extraction efficiency, toluene (which has relatively low vapor pressure) was found to provide the best extraction efficiency. The effects of sampling volume, organic solvent volume, syringe withdrawal rate, and number of extraction cycles were also investigated. The procedure with respect to repeatability and limits of detection was evaluated by soil spiked with chlorobenzenes. Repeatabilitywas between 5.7 and 17.7%, and the limits of detection were 6-14 ng/g. HS-LPME was shown to be an inexpensive, fast, and simple sample preparation method for volatile compounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Cited by
Sarafraz-Yazdi, A., & Amiri, A. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.10.003 · Cited by 779
Sample preparation techniques for the determination of trace residues and contaminants in foods
Ridgway, K., Lalljie, S. P. D., & Smith, R. M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.01.134 · Cited by 354
Critical review on recent developments in solventless techniques for extraction of analytes
Nerín, C., Salafranca, J., Aznar, M., & Batlle, R. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2437-6 · Cited by 284
Critical overview of selected contemporary sample preparation techniques
Ramos, L. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.11.011 · Cited by 280
KOZANI, R., ASSADI, Y., SHEMIRANI, F., HOSSEINI, M., & JAMALI, M. (2007) · Talanta · doi:10.1016/j.talanta.2006.10.039 · Cited by 264
Liquid-phase microextraction techniques within the framework of green chemistry
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.02.016 · Cited by 221
Tang, B., Bi, W., Zhang, H., & Row, K. H. (2014) · Chromatographia · doi:10.1007/s10337-013-2607-3 · Cited by 105
Single-Drop Microextraction in Bioanalysis
Choi, K., Kim, J., & Chung, D. S. (2011) · Bioanalysis · doi:10.4155/bio.11.3 · Cited by 42
Liquid phase microextraction techniques combined with chromatography analysis: a review
Dugheri, S., Mucci, N., Bonari, A., Marrubini, G., Cappelli, G., Ubiali, D., Campagna, M., Montalti, M., & Arcangeli, G. (2020) · Acta Chromatographica · doi:10.1556/1326.2019.00636 · Cited by 41
Greening Sample Preparation: New Solvents, New Sorbents
Ramos, L. (2020) · Challenges in Green Analytical Chemistry · doi:10.1039/9781788016148-00114 · Cited by 6
Metadata
- Authors
- Shen, G., & Lee, H. K.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-11-23
- Volume
- 75
- Issue
- 1
- Pages
- 98-103
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2089648766
- Cited by
- 168
- References
- 1
- FWCI
- 6.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.