Dynamic Three-Phase Microextraction as a Sample Preparation Technique Prior to Capillary Electrophoresis
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Dynamic three-phase (liquid-liquid-liquid) microextraction was developed for capillary electrophoresis. Four aromatic amines as model compounds were extracted from 4-mL aqueous samples adjusted to basic condition (donor solution) through a small volume of organic solvent impregnated in a hollow fiber, which was held by the needle of a conventional syringe, and retracted into a 5-microL acidic acceptor solution inside the syringe. A renewable organic film and aqueous sample plug were formed inside the hollow fiber with the repeated movement of the syringe plunger enabled by a programmable syringe pump. This is believed to be the first reported instance of a semiautomated dynamic liquid-liquid-liquid microextraction (LLLME) procedure. Following this microextraction, the 5-microL acceptor solution was analyzed by capillary zone electrophoresis (CE). This new technique provided approximately 140-fold enrichment in 20 min. Utilizing 4-chloroaniline as internal standard, dynamic LLLME could provide good reproducibility (<4.0%). In addition, this method allowed the direct transfer of extracted analytes to a CE system for analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prosen, H., & Zupančič-Kralj, L. (1999) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(98)00109-5 · Cited by 565
Developments in single-drop microextraction
Psillakis, E., & Kalogerakis, N. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(01)00126-1 · Cited by 373
Cited by
Developments in hollow fibre-based, liquid-phase microextraction
Rasmussen, K. E., & Pedersen-Bjergaard, S. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00105-0 · Cited by 520
Pedersen-Bjergaard, S., & Rasmussen, K. E. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.08.088 · Cited by 486
Lee, J., Lee, H. K., Rasmussen, K. E., & Pedersen-Bjergaard, S. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.06.050 · Cited by 398
Self-citationDadfarnia, S., & Haji Shabani, A. M. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.11.022 · Cited by 305
Liquid-phase microextraction techniques within the framework of green chemistry
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.02.016 · Cited by 221
Metadata
- Authors
- Hou, L., & Lee, H. K.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-04-24
- Volume
- 75
- Issue
- 11
- Pages
- 2784-2789
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2074358808
- Cited by
- 99
- References
- 2
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic Three-Phase Microextraction as a Sample Preparation Technique Prior to Capillary Electrophoresis. https://app.cochat.ai/papers/10.1021/ac020753z
- The paper
- Hou, L., & Lee, H. K. (2003). Dynamic Three-Phase Microextraction as a Sample Preparation Technique Prior to Capillary Electrophoresis. Analytical Chemistry. https://doi.org/10.1021/ac020753z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.