Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 387

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Identification and Relative Quantitation of Protein Mixtures by Enzymatic Digestion Followed by Capillary Reversed-Phase Liquid Chromatography−Tandem Mass Spectrometry

Bondarenko, Pavel V., Chelius, Dirk, Shaler, Thomas A.·2002·Analytical Chemistry

Abstract

In this report, we describe an approach for identification and relative quantitation of individual proteins within mixtures using LC/MS/MS analysis of protein digests. First, the proteins are automatically identified by correlating the tandem mass spectra with peptide sequences from a database. Then, peak areas of identified peptides from one protein are added together to define the total reconstructed peak area of the protein digest. The total reconstructed peak area is further normalized to the peak area of an internal standard protein digest present in the mixture at a constant level. The method was illustrated using digested mixtures of five standard proteins as follows. One protein was gradually diluted while the other four components were present in the mixtures at constant level. This study revealed that relative peak area of the variable protein increased linearly (trend line R2 = 0.9978) with increasing amount from 10 to 1000 fmol, while relative peak areas of four constant proteins remained approximately the same (within 20% relative standard deviation). To further evaluate the applicability of this method for the quantitation of proteins from complex mixtures, human plasma protein digest was spiked with 200 and 400 fmol of myoglobin digest. Total peak area of myoglobin peptides was normalized to the total peak area of apolipoprotein A-I peptides from human plasma, which played the role of an internal standard. The myoglobin/apolipoprotein A-I peak area ratio was 2 times larger for the human plasma digest spiked with a double amount of myoglobin. After several repetitions, the error of the relative peak area measurements remained below 11%, suggesting that the method described here can be used for relative concentration measurements of proteins in the complex biological mixtures. In the presented method, chemical derivatization steps are not needed to create an internal standard, as in isotope-coded affinity tag or similar methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac0256991

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 387

Metadata

Authors
Bondarenko, P. V., Chelius, D., & Shaler, T. A.
Venue
Analytical Chemistry
Published
2002-08-17
Volume
74
Issue
18
Pages
4741-4749
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2088697979
Cited by
387
References
18
FWCI
5.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Identification and Relative Quantitation of Protein Mixtures by Enzymatic Digestion Followed by Capillary Reversed-Phase Liquid Chromatography−Tandem Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac0256991
The paper
Bondarenko, P. V., Chelius, D., & Shaler, T. A. (2002). Identification and Relative Quantitation of Protein Mixtures by Enzymatic Digestion Followed by Capillary Reversed-Phase Liquid Chromatography−Tandem Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac0256991

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.