The DOI matches its Crossref record.
Derivatization of Ethinylestradiol with Dansyl Chloride To Enhance Electrospray Ionization: Application in Trace Analysis of Ethinylestradiol in Rhesus Monkey Plasma
Abstract
The extensive metabolism and administration of low doses of ethinylestradiol (EE) in preclinical animal species necessitates a sensitive analytical method to quantify the drug at low picogram-per-milliliter concentrations in biological matrixes. A highly sensitive and accurate method based on the derivatization of EE with dansyl chloride coupled with liquid chromatography/tandem mass spectrometry is described. The dansyl derivatization of EE introduced a basic secondary nitrogen into the molecule that was readily ionized in commonly used acidic HPLC mobile phases. The derivative showed an intense protonated molecular ion at m/z 530 under positive turbo ion spray ionization. The collision-induced dissociation of this ion formed a distinctive product at m/z 171, corresponding to the protonated 5-(dimethylamino)naphthalene moiety. The selected reaction monitoring, based on the m/z 530 --> 171 transition, was highly specific for EE, since no background signal was observed from blank plasma obtained from rhesus monkeys. The limit of detection, at a signal-to-noise ratio of 5, was 0.2 fg/mL EE spiked into blank plasma. This allowed for a lower limit of quantitation of 5 pg/mL using a 50-microL plasma sample and 10-microL injection of dansylated derivative into the CTC-PAL Leap autosampler coupled to a Sciex API 4000 mass spectrometer. Using fast-gradient liquid chromatography, the analyte peak eluted at 1.6 min. The validation results showed high accuracy (% bias < 4) and precision (% CV < 7.5) at broad linear dynamic ranges (0.005-20 ng/mL), using deuterated EE as internal standard. Therefore, the facile dansyl derivatization coupled with tandem mass spectral analysis allowed the development of a highly sensitive and specific method for quantitation of trace levels of EE in the plasma of rhesus monkeys dosed orally and intravenously with EE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent advances in sample preparation techniques for effective bioanalytical methods
Kole, P. L., Venkatesh, G., Kotecha, J., & Sheshala, R. (2011) · Biomedical Chromatography · doi:10.1002/bmc.1560 · Cited by 366
Micropollutant removal in an algal treatment system fed with source separated wastewater streams
de Wilt, A., Butkovskyi, A., Tuantet, K., Leal, L. H., Fernandes, T. V., Langenhoff, A., & Zeeman, G. (2016) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2015.10.033 · Cited by 305
Analytical strategies for identifying drug metabolites
Prakash, C., Shaffer, C. L., & Nedderman, A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20128 · Cited by 302
Xu, X., Roman, J. M., Issaq, H. J., Keefer, L. K., Veenstra, T. D., & Ziegler, R. G. (2007) · Analytical Chemistry · doi:10.1021/ac070494j · Cited by 260
A new strategy for ionization enhancement by derivatization for mass spectrometry
Iwasaki, Y., Nakano, Y., Mochizuki, K., Nomoto, M., Takahashi, Y., Ito, R., Saito, K., & Nakazawa, H. (2011) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.02.008 · Cited by 113
Metadata
- Authors
- Anari, M. R., Bakhtiar, R., Zhu, B., Huskey, S., Franklin, R. B., & Evans, D. C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-07-11
- Volume
- 74
- Issue
- 16
- Pages
- 4136-4144
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2024004800
- Cited by
- 196
- References
- 0
- FWCI
- 6.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Derivatization of Ethinylestradiol with Dansyl Chloride To Enhance Electrospray Ionization: Application in Trace Analysis of Ethinylestradiol in Rhesus Monkey Plasma. https://app.cochat.ai/papers/10.1021/ac025712h
- The paper
- Anari, M. R., Bakhtiar, R., Zhu, B., Huskey, S., Franklin, R. B., & Evans, D. C. (2002). Derivatization of Ethinylestradiol with Dansyl Chloride To Enhance Electrospray Ionization: Application in Trace Analysis of Ethinylestradiol in Rhesus Monkey Plasma. Analytical Chemistry. https://doi.org/10.1021/ac025712h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.