The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Interfacing the Orbitrap Mass Analyzer to an Electrospray Ion Source
Abstract
The orbitrap mass analyzer employs the trapping of pulsed ion beams in an electrostatic quadro-logarithmic field. This field is created between an axial central electrode and a coaxial outer electrode. Stable ion trajectories combine rotation around the central electrode with harmonic oscillations along it. The frequencies of axial oscillations and hence mass-to-charge ratios of ions are obtained using fast Fourier transform of the image current detected on the two split halves of the outer electrode. This work proves that such a trap could be coupled to a continuous, electrospray, ion source. Such a coupling necessitated the development of an rf-only quadrupole for external accumulation of ions and their injection in very short (< 1 micros) ion bunches. Along with good sensitivity, this mass spectrometer provides mass resolving power up to 150,000 fwhm, mass accuracies within a few parts per million, and relative mass range up to 8-fold. The maximum number of ions available for analysis is limited by the space-charge capacity of the accumulation quadrupole.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrostatic Axially Harmonic Orbital Trapping: A High-Performance Technique of Mass Analysis
Makarov, A. (2000) · Analytical Chemistry · doi:10.1021/ac991131p · Cited by 1,009
Self-citationInt. J. Mass Spectrom. Ion Processes
(1990) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(90)80022-u · Cited by 1,003
Senko, M. W., Hendrickson, C. L., Emmett, M. R., Shi, S. D. H., & Marshall, A. G. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00126-8 · Cited by 462
Proteome analysis using selective incorporation of isotopically labeled amino acids
Veenstra, T. D., Martinović, S., Anderson, G., Paša‐Tolić, L., & Smith, R. D. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00120-8 · Cited by 142
Limbach, P. A., Grosshans, P. B., & Marshall, A. G. (1993) · Analytical Chemistry · doi:10.1021/ac00050a008 · Cited by 95
Belov, M. E., Николаев, Е. Н., Harkewicz, R., et al. (2001) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(01)00434-1 · Cited by 50
Cited by
Olsen, J. V., de Godoy, L. M. F., Li, G., Macek, B., Mortensen, P., Pesch, R., Makarov, A., Lange, O., Horning, S., & Mann, M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500030-mcp200 · Cited by 1,510
Self-citationProteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
Michalski, A., Damoc, E., Hauschild, J.-P., Lange, O., Wieghaus, A., Makarov, A., Nagaraj, N., Cox, J., Mann, M., & Horning, S. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.011015 · Cited by 832
Self-citationA dual pressure linear ion trap orbitrap instrument with very high sequencing speed
Olsen, J. V., Schwartz, J. C., Griep-Raming, J., Nielsen, M. L., Damoc, E., Denisov, E., Lange, O., Remes, P., Taylor, D., Splendore, M., et al. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900375-mcp200 · Cited by 464
Self-citationZhang, Z., Wu, S., Stenoien, D. L., & Paša-Tolić, L. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020216 · Cited by 323
Metadata
- Authors
- Hardman, M., & Makarov, A. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-02-28
- Volume
- 75
- Issue
- 7
- Pages
- 1699-1705
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1994391661
- Cited by
- 314
- References
- 6
- FWCI
- 4.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interfacing the Orbitrap Mass Analyzer to an Electrospray Ion Source. https://app.cochat.ai/papers/10.1021/ac0258047
- The paper
- Hardman, M., & Makarov, A. A. (2003). Interfacing the Orbitrap Mass Analyzer to an Electrospray Ion Source. Analytical Chemistry. https://doi.org/10.1021/ac0258047
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.