Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 915

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Luminescent CdS Quantum Dots as Selective Ion Probes

Chen, Yongfen, Rosenzweig, Zeev·2002·Analytical Chemistry

Abstract

Water-soluble luminescent CdS quantum dots (QDs) capped by polyphosphate, L-cysteine, and thioglycerol were synthesized in aqueous solution. The ligands were found to have a profound effect on the luminesence response of CdS QDs to physiologically important metal cations. Polyphosphate-capped CdS QDs were sensitive to nearly all mono- and divalent cations, showing no ion selectivity. Conversely, thioglycerol-capped CdS QDs were sensitive to only copper and iron ions. Similar concentrations of physiologically relevant cations, such as zinc, sodium, potassium, calcium, and magnesium ions did not affect the luminescence of thioglycerol-capped CdS QDs. On the other hand, L-cysteine-capped CdS QDs were sensitive to zinc ions and insensitive to other physiologically important cations, such as copper, calcium, and magnium ions. To demonstrate the detection capability of these new ion probes, L-cysteine and thioglycerol-capped CdS QDs were used to detect zinc and copper ions in physiological buffer samples. The detection limits were 0.8 microM for zinc (II) and 0.1 microM for copper (II) ions. The emission enhancement of the QDs by zinc (II) is attributed to activation of surface states, whereas the effective reduction of copper (II) to copper (I) may explain the emission decrease of the thioglycerol-capped CdS QDs when charged with copper ions. Unlike organic fluorescent dyes, the thioglycerol-capped luminescent CdS QDs discriminate between copper and zinc ions and are therefore suitable for the analysis of copper ions in biological samples in the presence of physiological concentrations of zinc ions. The interference of iron ions with zinc and copper ion detection is attributed to an inner filter effect, which is eliminated by adding fluoride ions to form the colorless complex FeF6(3-). To the best of our knowledge, this is first use of luminescent semiconductor quantum dots as selective ion probes in aqueous samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac0258251

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 915

Metadata

Authors
Chen, Y., & Rosenzweig, Z.
Venue
Analytical Chemistry
Published
2002-08-23
Volume
74
Issue
19
Pages
5132-5138
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2071671615
Cited by
915
References
12
FWCI
9.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Luminescent CdS Quantum Dots as Selective Ion Probes. https://app.cochat.ai/papers/10.1021/ac0258251
The paper
Chen, Y., & Rosenzweig, Z. (2002). Luminescent CdS Quantum Dots as Selective Ion Probes. Analytical Chemistry. https://doi.org/10.1021/ac0258251

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.