The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Electrochemical Genosensor Based on Colloidal Gold Nanoparticles for the Detection of Factor V Leiden Mutation Using Disposable Pencil Graphite Electrodes
Abstract
Electrochemical genosensors for the detection of the Factor V Leiden mutation from polymerase chain reaction (PCR) amplicons using the oxidation signal of colloidal gold (Au) is described. A pencil graphite electrode (PGE) modified with target DNA, when hybridized with complementary probes conjugated to Au nanoparticles, responded with the appearance of a Au oxide wave at approximately +1.20 V. Specific probes were immobilized onto the Au nanoparticles in two different modes: (a) Inosine-substituted probes were covalently attached from their amino groups at the 5' end using N-(3-dimethylamino)propyl)-N'-ethylcarbodiimide hydrochloride (EDC) and N-hydroxysulfosuccinimide (NHS) as a coupling agent onto a carboxylate-terminated l-cysteine self-assembled monolayer (SAM) preformed on the Au nanoparticles, and (b) probes with a hexanethiol group at their 5' phosphate end formed a SAM on Au nanoparticles. The genosensor relies on the hybridization of the probes with their complementary targets, which are covalently immobilized at the PGE surface. Au-tagged 23-mer capture probes were challenged with the synthetic 23-mer target, 131-base single-stranded DNA or denatured 256-base polymerase chain reaction (PCR) amplicon. The appearance of the Au oxidation signal shortened the assay time and simplified the detection of the Factor V Leiden mutation from PCR amplified real samples. The discrimination between the homozygous and heterozygous mutations was also established by comparing the peak currents of the Au signals. Numerous factors affecting the hybridization and nonspecific binding events were optimized. The detection limit for the PCR amplicons was found to be as low as 0.78 fmol; thus, it is suitable for point-of-care applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elghanian, R., Storhoff, J. J., Mucic, R. C., Letsinger, R. L., & Mirkin, C. A. (1997) · Science · doi:10.1126/science.277.5329.1078 · Cited by 4,399
Mutation in blood coagulation factor V associated with resistance to activated protein C
Bertina, R. M., Koeleman, B. P. C., Koster, T., Rosendaal, F. R., Dirven, R. J., de Ronde, H., van der Velden, P. A., & Reitsma, P. H. (1994) · Nature · doi:10.1038/369064a0 · Cited by 3,783
Storhoff, J. J., Elghanian, R., Mucic, R. C., Mirkin, C. A., & Letsinger, R. L. (1998) · Journal of the American Chemical Society · doi:10.1021/ja972332i · Cited by 2,271
Efficient Near-Infrared Polymer Nanocrystal Light-Emitting Diodes
Tessler, N., Medvedev, V., Kazes, M., Kan, S., & Banin, U. (2002) · Science · doi:10.1126/science.1068153 · Cited by 1,361
Demers, L. M., Mirkin, C. A., Mucic, R. C., Reynolds, R. A., Letsinger, R. L., Elghanian, R., & Viswanadham, G. (2000) · Analytical Chemistry · doi:10.1021/ac0006627 · Cited by 1,109
Electrochemical DNA Hybridization Biosensors
Gooding, J. J. (2002) · Electroanalysis · doi:10.1002/1521-4109(200209)14:17<1149::aid-elan1149>3.0.co;2-8 · Cited by 480
Two-Color Labeling of Oligonucleotide Arrays via Size-Selective Scattering of Nanoparticle Probes
Taton, T. A., Lu, G., & Mirkin, C. A. (2001) · Journal of the American Chemical Society · doi:10.1021/ja0102639 · Cited by 403
An Electrochemical Metalloimmunoassay Based on a Colloidal Gold Label
Dequaire, M., Degrand, C., & Limoges, B. (2000) · Analytical Chemistry · doi:10.1021/ac000781m · Cited by 379
Authier, L., Grossiord, C., Brossier, P., & Limoges, B. (2001) · Analytical Chemistry · doi:10.1021/ac0103221 · Cited by 328
Yang, W., Justin Gooding, J., & Brynn Hibbert, D. (2001) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(01)00649-0 · Cited by 274
Cited by
Daniel, M.-C., & Astruc, D. (2004) · Chemical Reviews · doi:10.1021/cr030698+ · Cited by 12,446
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
DNA Biosensors and Microarrays
Sassolas, A., Leca-Bouvier, B. D., & Blum, L. J. (2008) · Chemical Reviews · doi:10.1021/cr0684467 · Cited by 1,246
Gold nanoparticle-based electrochemical biosensors
Pingarrón, J. M., Yáñez-Sedeño, P., & González-Cortés, A. (2008) · Electrochimica Acta · doi:10.1016/j.electacta.2008.03.005 · Cited by 965
Metadata
- Authors
- Ozsoz, M., Erdem, A., Kerman, K., Ozkan, D., Tugrul, B., Topcuoglu, N., Ekren, H., & Taylan, M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-04-03
- Volume
- 75
- Issue
- 9
- Pages
- 2181-2187
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2048769537
- Cited by
- 273
- References
- 19
- FWCI
- 6.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical Genosensor Based on Colloidal Gold Nanoparticles for the Detection of Factor V Leiden Mutation Using Disposable Pencil Graphite Electrodes. https://app.cochat.ai/papers/10.1021/ac026212r
- The paper
- Ozsoz, M., Erdem, A., Kerman, K., Ozkan, D., Tugrul, B., Topcuoglu, N., Ekren, H., & Taylan, M. (2003). Electrochemical Genosensor Based on Colloidal Gold Nanoparticles for the Detection of Factor V Leiden Mutation Using Disposable Pencil Graphite Electrodes. Analytical Chemistry. https://doi.org/10.1021/ac026212r
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.