Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 273

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Electrochemical Genosensor Based on Colloidal Gold Nanoparticles for the Detection of Factor V Leiden Mutation Using Disposable Pencil Graphite Electrodes

Ozsoz, Mehmet, Erdem, Arzum, Kerman, Kagan, Ozkan, Dilsat, Tugrul, Berrin, Topcuoglu, Nejat, Ekren, Hayati, Taylan, Muzaffer·2003·Analytical Chemistry

Abstract

Electrochemical genosensors for the detection of the Factor V Leiden mutation from polymerase chain reaction (PCR) amplicons using the oxidation signal of colloidal gold (Au) is described. A pencil graphite electrode (PGE) modified with target DNA, when hybridized with complementary probes conjugated to Au nanoparticles, responded with the appearance of a Au oxide wave at approximately +1.20 V. Specific probes were immobilized onto the Au nanoparticles in two different modes: (a) Inosine-substituted probes were covalently attached from their amino groups at the 5' end using N-(3-dimethylamino)propyl)-N'-ethylcarbodiimide hydrochloride (EDC) and N-hydroxysulfosuccinimide (NHS) as a coupling agent onto a carboxylate-terminated l-cysteine self-assembled monolayer (SAM) preformed on the Au nanoparticles, and (b) probes with a hexanethiol group at their 5' phosphate end formed a SAM on Au nanoparticles. The genosensor relies on the hybridization of the probes with their complementary targets, which are covalently immobilized at the PGE surface. Au-tagged 23-mer capture probes were challenged with the synthetic 23-mer target, 131-base single-stranded DNA or denatured 256-base polymerase chain reaction (PCR) amplicon. The appearance of the Au oxidation signal shortened the assay time and simplified the detection of the Factor V Leiden mutation from PCR amplified real samples. The discrimination between the homozygous and heterozygous mutations was also established by comparing the peak currents of the Au signals. Numerous factors affecting the hybridization and nonspecific binding events were optimized. The detection limit for the PCR amplicons was found to be as low as 0.78 fmol; thus, it is suitable for point-of-care applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac026212r

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 273

Metadata

Authors
Ozsoz, M., Erdem, A., Kerman, K., Ozkan, D., Tugrul, B., Topcuoglu, N., Ekren, H., & Taylan, M.
Venue
Analytical Chemistry
Published
2003-04-03
Volume
75
Issue
9
Pages
2181-2187
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2048769537
Cited by
273
References
19
FWCI
6.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrochemical Genosensor Based on Colloidal Gold Nanoparticles for the Detection of Factor V Leiden Mutation Using Disposable Pencil Graphite Electrodes. https://app.cochat.ai/papers/10.1021/ac026212r
The paper
Ozsoz, M., Erdem, A., Kerman, K., Ozkan, D., Tugrul, B., Topcuoglu, N., Ekren, H., & Taylan, M. (2003). Electrochemical Genosensor Based on Colloidal Gold Nanoparticles for the Detection of Factor V Leiden Mutation Using Disposable Pencil Graphite Electrodes. Analytical Chemistry. https://doi.org/10.1021/ac026212r

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.